Development of a design factor for activated sludge sedimentation tank design based on batchsettling data
Abstract
dc:description.abstractA simple technique is presented to obtain a design factor for activated sludge sedimentation tank design to account for periodic changes in slurry settling characteristics. Currently, only changes in hydraulic and solids loading are typically accounted for during design. The technique presented is based on performing repetitive batch settling tests, the results of which were used to relate slurry concentration to settling velocity for a municipal activated sludge system through the first-order Vesilind equation (V = V0 exp (-KC)). The parameters V0 and K of the Vesilind equation were calculated by non-linear least squares parameter estimation. The value of the operating flux (G0 ) was then calculated and was used as a representation of the settling characteristics for each set of data. A statistical analysis was then performed to describe the distribution of G0 values collected over an approximately 6-month period. The distribution of the G0 values was found to be log normal.From the results of the distribution analysis, safety factors were determined for various required levels of confidence. The results of this study can be used for activated sludge sedimentation tank design by applying the same statistical distribution to a single data point which is assumed to be descriptive of average settling characteristics. For a 95 percent level of confidence the value of this design factor was approximately 1.85.
Degree
thesis:*- Grantor dc:publisher
- University of Central Florida
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Tanke, Paul D.
- Contributors dc:contributor
-
- Dietz, John D.
Subjects
dc:subject × 4Rights
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
- DP0029747