In current design practice the components of the complete mix activated sludge system are designed as individual units with little or no appreciation for the process interactions which occur between system components. To achieve acceptable process efficiency and to realize cost effectiveness a unified design approach is necessary. This research effort was initiated to define the characteristics of the economic optimum complete mix activated sludge configuration while considering system interactions. A computer program was developed for the completion of the process design and the economic analysis of the aeration basins, the settling basins, and the return sludge pumping facilities for the complete mix activated sludge system. The process design was formulated subject to constraints on the following: effluent suspended solids effluent substrate concentration underflow solids concentration maximum and minimum mixed liquor suspended solids concentration maximum and minimum values for settling basin depth Recognizing the importance of the final settling basin to the overall economics and performance of the activated sludge process emphasis was placed on settling basin design. Settling basin surface area requirements for thickening were identified using the settling flux approach. To ensure comparison of systems capable of producing equivalent effluent qualities settling basin performance was evaluated using a model reported in the literature. The model selected shows sensitivity to settling basin detention time, overflow rate and mixed liquor suspended solids concentration. Using the optimization routine, simulations were performed to identify the optimum system configuration as defined by this model. The optimum system aeration basin hydraulic detention times were found to be higher than those typically used, while the optimum system mixed liquor suspended solids concentrations were found to be lower than those typically used. Optimum system settling basin hydraulic detention times and depths were found to exceed conventional detention times and depths in current usage. Although the optimization routine developed in this research may not have wide spread applicability, the results are felt to be significant in identifying optimum system trends.

Degree

thesis:*
Grantor dc:publisher
University of Central Florida

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Huguenard, Robert P.
Contributors dc:contributor
  • Dietz, John D.
  • <p><a href="https://viaf.org/viaf/39460503">Dietz, John D.</a> [VIAF]</p> <p><a href="http://id.loc.gov/authorities/names/n85317632">Dietz, John D.</a> [LC]</p><p><a href="http://viaf.org/viaf/155956728">University of Central Florida. College of Engineering</a> [VIAF]</p><p><a href="http://id.loc.gov/authorities/names/n82027354.html">University of Central Florida. College of Engineering</a> [LC]</p>

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • Public Domain
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
DP0020357

Chain of custody

source
Harvested from
Central Florida
Base URL
stars.library.ucf.edu/do/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Huguenard, Robert P.. Cost Effective Design of the Activated Sludge Wastewater Treatment System. University of Central Florida, https://stars.library.ucf.edu/rtd/4947