Back to search

UCL (University College London)

Optimization and new applications of edge-illumination based X-ray phase contrast CT

Abstract

dc:description.abstract

The Edge Illumination (EI) method is a phase contrast imaging technique suitable for use with conventional X-ray sources, which has demonstrated its great potential for translation into real-world environments. The increase in image contrast provided by it, in particular for low-absorbing materials, along with its ability to be operated as a computed tomography (CT) modality, make it an especially advantageous technique for biomedical applications. The work presented in this thesis aimed to develop new image acquisition and processing strategies to further advance the current capabilities of EI CT, such that it could be used in a robust way for a wide range of biomedical applications. This was achieved by the development of two retrieval algorithms, which are required for the extraction of quantitative information of various sample properties. The first algorithm targets applications which involve high-resolution, multi-modal lab-based CT scans. It has been shown that, during these long scans, the variation in system parameters across the field-of-view and over time can lead to significant image artefacts in reconstructed CT slices. The proposed algorithm is capable of correcting for both types of variations, leading to the quantitative retrieval of sample properties from long CT scans in non-ideal environments. The second algorithm was aimed at applications which require fast CT scans, possibly at the expense of spatial resolution and quantitative information. A previously developed algorithm enabled a substantial reduction in scan times for homogeneous samples, by reducing the number of required images per angular view. The new algorithm presented here has extended the previous one to non-homogeneous samples, therefore expanding the range of objects which could benefit from a reduction in scan times through use of this approach. In addition, perinatal post-mortem imaging has been identified as a new biomedical application which could benefit from EI CT in the future. Promising results are reported from a proof-of-principle scan carried out using a gold standard X-ray phase contrast imaging method at a synchrotron.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zamir, Anna

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10026001/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Zamir, Anna. Optimization and new applications of edge-illumination based X-ray phase contrast CT. Doctoral thesis, UCL (University College London), 2017. https://discovery.ucl.ac.uk/id/eprint/10026001/