Back to search

UCL (University College London)

Investigating the ultrastructure of enamel white spot lesions (WSL) using Optical Coherence Tomography at different length scales

Abstract

dc:description.abstract

White spot lesion (WSL) is the clinical presentation of early caries, which is a demineralisation that occurs at subsurface level, with a well-mineralised surface layer enclosing the lesion. Early diagnosis and treatment of WSL is crucial to prevent further destruction of tooth structure. The aim of this research is to investigate the potential of optical coherence tomography (OCT) to be used as an adjunct diagnostic clinical tool to evaluate the severity of such lesions. This research also compared the OCT outputs with traditional histology, X-ray Microtomography (XMT), Synchrotron X-ray Diffraction (SXRD) and Scanning Electron microscope (SEM). All specimens were collected from patients undergoing dental treatment at Eastman Dental Hospital with informed consent following ethical approvall. Initially, Artificial WSLs were induced on sound enamel surfaces using a buffered methylcellulose gel system at pH 4.6 for 7 and 14 days. Type-matched native WSL and healthy control teeth were selected based on ICDAS for comparison. Imaging of samples was obtained using OCT of whole teeth and by polarised microscopy, SXRD, XMT and SEM of polished 250 μm thick sections. Polarised microscope, XMT and SEM confirmed the findings of the OCT results. Images showed that the more back scattered signals recorded, the deeper the destruction throughout enamel thickness. SXRD results showed changes in enamel texture, which was interpreted from measuring crystallite orientations and lattice parameter. SXRD result showed some correlation with OCT images, however more investigation is required to confirm the findings. In conclusion, the variations observed in the back-scattered light in OCT experiment were because of mineral density variation within enamel structure, as well as the changes in prismatic structure and may be related to crystallite texture and orientation. OCT has shown to be a reliable non-destructive technique, that can investigate the internal structure, by measuring the back-scattered light from materials such as enamel and dentine. In healthy samples, OCT B-scans showed a homogenous pattern of scattering intensity throughout enamel structure, indicating healthy structure, while in both natural and induced white spot lesions, a non homogenous scattering intensity was observed, indicating changes in enamel structure.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sarkhouh, Shaima Mansour
Contributors dc:contributor
  • Bozec, L
  • Parekh, S
  • Al-Jawad, M

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10040047/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Sarkhouh, Shaima Mansour. Investigating the ultrastructure of enamel white spot lesions (WSL) using Optical Coherence Tomography at different length scales. Doctoral thesis, UCL (University College London), 2017. https://discovery.ucl.ac.uk/id/eprint/10040047/