Back to search

UCL (University College London)

Development of a safety system and contaminant quantification methods for use within a bioartificial liver device

Abstract

dc:description.abstract

The prognosis for patients with acute liver failure is poor, as such a novel method for the treatment of these patients is urgently required. The Liver Group bioartificial liver (BAL) has been developed to meet this need. The BAL consists of an extracorporeal circuit, in which the patient’s plasma is processed through an alginate-encapsulated HepG2 cellular biomass. These cells synthesise proteins and perform a detoxification function, replacing that of the patient’s own liver. The aim of this PhD thesis was to characterise a filtration system for incorporation within the BAL, enabling regulatory requirements for use in patients to be met. Specifically, the system was to remove potential contaminants originating from the biomass, such as cell debris and DNA. The filtration system was to also be assessed for the removal of endotoxin, originating from the patient as a cofactor of their liver failure, to aid the patient’s recovery. This thesis led to the development of a protocol for the incorporation of a filtration system into the BAL. Assays for the detection of DNA and endotoxin within human plasma samples were successfully optimised for use both in vitro and in vivo. These assays enabled the detection of DNA and endotoxin at a lower level concentration of 0.1 ng/µl and 1 EU/ml, respectively, facilitating characterisation of the safety system to sufficient sensitivity limits required to meet regulatory guidelines. DNA, endotoxin and particles were consistently removed from plasma samples by the filtration system, whilst beneficial components of the plasma such as albumin and fibrinogen, native to the patient or produced by the biomass, were maintained. To conclude, this thesis demonstrates that the filtration system was able to remove potential BAL-originating contaminants, meeting regulatory guidelines to enable its use in patients. The filtration system also demonstrated endotoxin removal capacity, providing an additional functional element of this system.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gibbons, Stephanie Annie

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10040316/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Gibbons, Stephanie Annie. Development of a safety system and contaminant quantification methods for use within a bioartificial liver device. Doctoral thesis, UCL (University College London), 2017. https://discovery.ucl.ac.uk/id/eprint/10040316/