Back to search

UCL (University College London)

Non-destructive detection of counterfeit and substandard medicines using X-ray diffraction

Abstract

dc:description.abstract

The prevalence of counterfeit and substandard medicines has been growing rapidly over the past decade, and fast, non-destructive techniques for their detection are urgently needed to counter this trend. In this thesis, both energy-dispersive X-ray diffraction (EDXRD) and pixelated diffraction (“PixD”) combined with chemometric methods were assessed for their effectiveness in detecting poor-quality medicines within their packaging. Firstly, a series of caffeine, paracetamol and cellulose mixtures of known concentrations were pressed into tablets. EDXRD spectra of each tablet were collected both with and without packaging. Principal component analysis (PCA) and partial least-squares regression (PLSR) were used to study the data and construct calibration models for quantitative analysis. The concentration prediction errors for the packaged data were found to be very similar to those obtained in the unpackaged case, and were also on a par with reported values in the literature using higher-resolution angular-dispersive X-ray diffraction (ADXRD). Following this, soft independent modelling by class analogy (SIMCA) classification was used to compare EDXRD spectra from a test set of over-the-counter (OTC) medicines containing various combinations of active pharmaceutical ingredients (APIs) against PCA models constructed using spectra collected for paracetamol and ibuprofen samples. The test samples were selected to emulate different levels of difficulty in authenticating medicines correctly, ranging from completely different APIs (easy) to those with a small quantity of additional API (difficult). This classification study found that the sensitivity and specificity were optimal at data acquisition times on the order of 75~150s, and regardless of whether layers of blister and card packaging surrounded the tablet in question. This experiment was repeated on a novel, compact system incorporating a pixellated detector, which was found to reduce the required data acquisition times for optimal classification by a factor of five.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Crews, CCE
Contributors dc:contributor
  • Speller, R

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10047187/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Crews, CCE. Non-destructive detection of counterfeit and substandard medicines using X-ray diffraction. Doctoral thesis, UCL (University College London), 2018. https://discovery.ucl.ac.uk/id/eprint/10047187/