Back to search

UCL (University College London)

Development and application of diffuse optical tomography systems for diagnosis and assessment of perinatal brain injury

Abstract

dc:description.abstract

Diffuse optical tomography (DOT) was investigated as a means of non-invasively monitoring neonatal brain function at the cot-side. Two DOT devices designed and built at UCL were used in this work: a continuous-wave (CW-DOT) system and a time-resolved (TR-DOT) system known as MONSTIR II. Both systems are sensitive to changes in absorption within the interrogated tissue and can be used to create images of relative changes in oxy- and deoxyhaemoglobin concentration. MONSTIR II also has the capacity to isolate changes in absorption from those in scattering by obtaining photon flight-time information. These DOT devices were used to explore whether infant neuropathologies, such as perinatal arterial ischaemic stroke (PAIS), can be detected earlier than is currently achieved clinically. To test the efficacy of DOT for early PAIS diagnosis, stroke-affected infants were initially studied with a CW-DOT system. Significant differences in interhemispheric correlation were found between the control group and the PAIS group, with the latter having impaired connectivity in the frequency range of 0.0055-0.080 Hz. The efficacy of MONSTIR II for imaging similar neuropathological infants was evaluated using a complex anatomically-accurate neonatal head phantom created using a novel 3D printing technique. To experimentally determine the optimal combination of near-infrared wavelengths for studying brain function with MONSTIR II, a widely applicable systems-testing protocol based on functional activation was developed. To mitigate the inherently slow sampling of TR-DOT systems, a variational form Kalman filter (VKF) was implemented to improve the spatio-temporal resolution of MONSTIR II for imaging transient neuropathological events. The VKF was tested on two dynamic phantoms designed to mimic neonatal seizures. Finally, MONSTIR II was used to acquire data from healthy and brain injured infants. Preliminary results from a neonate with PAIS suggest a significant asymmetry between hemispheres for wavelength intensity ratio data.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dempsey, Laura Alicia

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10047766/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Dempsey, Laura Alicia. Development and application of diffuse optical tomography systems for diagnosis and assessment of perinatal brain injury. Doctoral thesis, UCL (University College London), 2018. https://discovery.ucl.ac.uk/id/eprint/10047766/