Back to search

UCL (University College London)

Improving X-ray CT Dimensional Metrology with Simple Holeplates

Abstract

dc:description.abstract

X-ray computed tomography (XCT) is increasingly being used for the internal and external dimensional measurement of objects in many sectors. However, multiple factors affect the accuracy and precision of these dimensional measurements. Initial work found errors associated with the intensity and spectrum of the X-ray flux, both spatially and temporally over the imaging period. These variables were measured using a single ionisation chamber, an ionisation chamber array and a spectrometer, and their effects on dimensional metrology are discussed. The main focus of this work is on the apparent surface deformation of the reconstructed holes within a holeplate. Measurements of a complex holeplate with multiple holes highlighted systematic deformations in the reconstructed geometry (± 60 µm) for a 2 mm radius hole. Observed systematic deformation patterns were correlated with holeplate orientation. The simplification needed to understand the problem was achieved through practical testing and numerical simulation of simple holeplates, each containing a single hole. Similar trends in the systematic deformation patterns between complex and simple holeplates were found with deformations in the geometry of ±30 µm for a 2 mm radius hole. Algorithms using a ray tracing method were used to simulate X-ray images which were subsequently reconstructed. Results had the same trends in deformation as the experimental data but were of a smaller magnitude, probably due to scatter not being modelled in the simulation. Systematic deformation in the reconstructed geometry of the holes is caused by multiple factors: the orientation of the holeplate during imaging; the largest errors (<60 µm) were found when the holeplate was orientated at 45° to horizontal. The path length of the X-rays through the material and errors of <40 µm highlighted a correlation between the hole and the centre of rotation. Understanding these factors is essential to traceability in dimensional measurements using XCT.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Corcoran, Hannah Clare
Contributors dc:contributor
  • Robson, S
  • Speller, R

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10063941/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Corcoran, Hannah Clare. Improving X-ray CT Dimensional Metrology with Simple Holeplates. Doctoral thesis, UCL (University College London), 2018. https://discovery.ucl.ac.uk/id/eprint/10063941/