UCL (University College London)
Penalised image reconstruction algorithms for efficient and consistent quantification in emission tomography
Abstract
dc:description.abstractWith the increased interest in potential clinical applications based on quantitative results, the aim of this study is to improve the quantitative consistency of the reconstructed images in emission tomography (ET). To achieve practical processing time, a fast convergent quasi-Newton algorithm, preconditioned limited-memory Broyden-Fletcher-Goldfarb-Shanno with boundary constraints (L-BFGS-B-PC), is firstly proposed. Its performance is eval- uated using both simulations and three patient datasets. Results show that L-BFGS-B-PC is able to achieve several times faster convergence rate than separable paraboloidal surrogates (SPS). Moreover, the performance is less sensitive to penalty type, penalty strength, noise level and background level, compared to L-BFGS-B. To be able to improve the image quality and quantitative consistency, an anatomical penalty function is then considered with a spatially-variant penalty strength. Based on results for simulations and data from one patient with inserted pseudo lesions, the spatially-variant penalty reduces the quantitative dependence on the surrounding activity and location. Moreover, it benefits the algorithm convergence rate and its consistency among datasets. It is important to consider potential misalignment between the functional and anatomical images. For this reason, two approaches that perform alternating pe- nalised image reconstruction and misalignment estimation are therefore proposed. Expanding on the previous work, L-BFGS-B-PC using Parallel Level Sets (PLS) with the spatially-variant penalty strength is used in both approaches. Preliminary results for non-time-of-flight (non-TOF) data simulations demonstrate that both methods are able to estimate the misalignment and deform the anatomical image accordingly when a proper workflow for the alternating optimisation is applied. By integrating algorithms proposed in this study, both good image quality and consistent quantification can be achieved in a practical processing time.
Degree
thesis:*- Level dc:type.qualificationlevel
- Doctoral
- Grantor dc:publisher.institution
- UCL (University College London)
- Year dc:date.issued
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Tsai, Yu-Jung
Rights
- Language dc:language
- en, eng
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- https://discovery.ucl.ac.uk/id/eprint/10065963/