Abstract

dc:description.abstract

With the increased interest in potential clinical applications based on quantitative results, the aim of this study is to improve the quantitative consistency of the reconstructed images in emission tomography (ET). To achieve practical processing time, a fast convergent quasi-Newton algorithm, preconditioned limited-memory Broyden-Fletcher-Goldfarb-Shanno with boundary constraints (L-BFGS-B-PC), is firstly proposed. Its performance is eval- uated using both simulations and three patient datasets. Results show that L-BFGS-B-PC is able to achieve several times faster convergence rate than separable paraboloidal surrogates (SPS). Moreover, the performance is less sensitive to penalty type, penalty strength, noise level and background level, compared to L-BFGS-B. To be able to improve the image quality and quantitative consistency, an anatomical penalty function is then considered with a spatially-variant penalty strength. Based on results for simulations and data from one patient with inserted pseudo lesions, the spatially-variant penalty reduces the quantitative dependence on the surrounding activity and location. Moreover, it benefits the algorithm convergence rate and its consistency among datasets. It is important to consider potential misalignment between the functional and anatomical images. For this reason, two approaches that perform alternating pe- nalised image reconstruction and misalignment estimation are therefore proposed. Expanding on the previous work, L-BFGS-B-PC using Parallel Level Sets (PLS) with the spatially-variant penalty strength is used in both approaches. Preliminary results for non-time-of-flight (non-TOF) data simulations demonstrate that both methods are able to estimate the misalignment and deform the anatomical image accordingly when a proper workflow for the alternating optimisation is applied. By integrating algorithms proposed in this study, both good image quality and consistent quantification can be achieved in a practical processing time.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tsai, Yu-Jung

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10065963/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Tsai, Yu-Jung. Penalised image reconstruction algorithms for efficient and consistent quantification in emission tomography. Doctoral thesis, UCL (University College London), 2019. https://discovery.ucl.ac.uk/id/eprint/10065963/