Back to search

UCL (University College London)

Acoustic resolution photoacoustic flowmetry

Abstract

dc:description.abstract

Acoustic Resolution PhotoAcoustic Flowmetry (AR-PAF) is a young and promising flow speed imaging modality based on the photoacoustic effect. The photoacoustic effect is the generation of ultrasound upon absorption of light. Utilising this effect for imaging of vasculature allows for optical contrast while maintaining the deep tissue imaging capabilities inherent to medical ultrasound. Owing to the excellent optical contrast of blood, it is thought that AR-PAF can achieve non-invasive imaging of spatially resolved flow maps. In order to characterise the capabilities of AR-PAF with regards to physiological blood flow phenomena (RBC aggregation, RBC heterogeneity and flow unsteadiness), a dual-mode imaging setup was developed, capable of acquiring photoacoustic signals concurrently with optical microscopy images. This involved development of novel microfluidic channels with unique imaging characteristics to allow both acoustic interrogation for photoacoustic imaging as well as optical microscopy imaging using Particle Image Velocimetry (PIV). This allowed both blood microstructure and flow velocity to be resolved simultaneously. AR-PAF and PIV were simultaneously performed under the challenging conditions of fast data acquisition (10 frames per measurement), highlighting the possibility of real- time measurements. Novel processing methods were developed to extract spatially resolved velocity information from the measured photoacoustic signals. The effects of increasing displacement and increasing velocity were analysed independently in order to identify optimal imaging conditions. Compelling agreement between optical and photoacoustic flow measurements was achieved indicating that AR-PAF can accurately measure microscale blood flow velocities. AR-PAF was found to be robust, performing accurately even beyond physiological RBC concentrations. Furthermore, it was found that physiological RBC aggregation did not significantly affect the performance of AR-PAF. Lastly, the developed methods were used to demonstrate successful AR-PAF measurements using a clinical ultrasound scanner and whole blood. This study highlighted that clinical translation of AR-PAF should be the next step in development of this promising modality.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bücking, Thore Mainart

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10079090/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Bücking, Thore Mainart. Acoustic resolution photoacoustic flowmetry. Doctoral thesis, UCL (University College London), 2019. https://discovery.ucl.ac.uk/id/eprint/10079090/