Back to search

UCL (University College London)

Development of non-invasive MRI to measure water permeability across the blood-brain interface

Abstract

dc:description.abstract

The blood-brain interface (BBI) is a physical and biochemical barrier that protects and maintains healthy brain function. Disruption of the BBI is indicative of the early stages of certain neurodegenerative diseases, such as Alzheimer’s Disease. However, there is currently a lack of sensitive tools available to accurately quantify the early alterations to the integrity of the BBI. This thesis describes the development and implementation of multiple echo time arterial spin labelling (multi-TE ASL) MRI technique in the mouse brain to measure vascular water permeability across the BBI. The technique was implemented in two high-field MRI system to demonstrate the consistency of the imaging protocols and the sensitivity of the measures of BBI water permeability. The multi-TE ASL technique was used to probe the function of aquaporin-4 (AQP4) water channels, which play a key role in the clearance of the deleterious proteins from the brain. This non-invasive technique was able to demonstrate its sensitivity to targeting AQP4 by measuring a 31% slowing of cortical BBI water permeability with the removal of the AQP4 water channels. The technique also measured a 34% slowing in the BBI water permeability in the cerebellum brain region with a reduction of AQP4 channels at the BBI. Finally, the technique measured a 32% increase in cortical BBI permeability to water in a mouse model of ageing. The non-invasive imaging measurements were 7 associated with a 2-fold increase in mRNA expression of pericytes, while other BBI markers such as tight junction proteins were maintained. Overall, this work has demonstrated the scope of novel MRI technique to target changes to BBI water permeability, with potential for clinical translation for the early detection and understanding of neurodegenerative disease.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ohene, Yolanda

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10091166/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Ohene, Yolanda. Development of non-invasive MRI to measure water permeability across the blood-brain interface. Doctoral thesis, UCL (University College London), 2020. https://discovery.ucl.ac.uk/id/eprint/10091166/