Multiscale dual-mode photoacoustic imaging with a Fabry-Pérot scanner

Abstract

dc:description.abstract

This thesis proposes the design of a dual-mode photoacoustic tomography and optical-resolution photoacoustic microscopy scanner. Photoacoustic tomography can visualise larger blood vessels in the skin with a penetration depth of up to 1 cm. Optical-resolution photoacoustic microscopy can image the microvasculature at a capillary level in the skin with a penetration depth of up to 1 mm. A combination of both modes will result in images that have both, larger penetration depths from the tomography mode and high resolution in superficial depths from the microscopy mode. The integration of both modes in one scanner is straightforward if the scanner is based on the Fabry-Perot ultrasound sensor since it is transparent to the excitation wavelength image. A dual-mode Fabry-Perot based scanner has been reported before but modifications are needed for successful in vivo imaging. Dual-mode piezoelectric detector based scanners have not been proposed so far. This thesis describes the work that was undertaken to improve the performance of both scanners and achieve dual-mode photoacoustic tomography (PAT) and optical-resolution microscopy (OR-PAM). A novel laser-scanning optical-resolution photoacoustic microscopy system (LSOR-PAM) was developed and integrated into the same scanner. The system performance was assessed individually for all setups. PAT, OR-PAM and LSOR-PAM images were taken successfully from various phantoms and a mouse ear (ex vivo). A large part of the work that was undertaken in preparation of dual-mode image acquisition was the design of a novel Fabry-Perot sensor. The original design of the mirrors that form the Fabry-Perot cavity has been analysed in detail. The effect of changes in the mirror design and the effect of uncertainties arising from the manufacturing process of the mirrors were analysed. Based on the results of this analysis a new design for the mirrors was proposed. The new sensor is transparent at excitation wavelengths for both PAT and OR-PAM/LSOR-PAM.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Brand, Sophie

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10092230/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Brand, Sophie. Multiscale dual-mode photoacoustic imaging with a Fabry-Pérot scanner. Doctoral thesis, UCL (University College London), 2020. https://discovery.ucl.ac.uk/id/eprint/10092230/