Back to search

UCL (University College London)

Quantification aspects of chemical exchange saturation transfer MRI

Abstract

dc:description.abstract

Chemical exchange saturation transfer (CEST) is a magnetic resonance imaging (MRI) acquisition technique that generates an image contrast based on proton exchange processes between water molecules and metabolites. This contrast depends on several parameters, for example metabolite concentration and exchange rate which can be used to characterize pathologies such as stroke or cancer. The quantification of these parameters is important because they fully describe the CEST processes and represent sequence and scanner independent biomarkers. However, in vivo the quantification of CEST parameters is difficult because of the high number of different CEST metabolites and their highly correlated model parameters, as well as confounding effects that contribute to the measured signal. Furthermore, the general mathematical model that describes the exchange processes is computationally demanding and requires long processing times. The aim of this thesis was to develop methods for the improved quantification of CEST parameters. To address both, the parameter correlations and the long processing times, a Bayesian fitting algorithm was combined with approximate analytical solutions of the general model equations. A significant reduction of computational time was achieved when fitting continuous-wave saturation data (about 50-fold) and pulsed saturation data (more than 100-fold) with the analytical approximation while the estimated parameters were largely consistent with the parameters from the general numerical solution. In vivo the algorithm was evaluated based on healthy mouse data from a 9.4T animal scanner. Furthermore, an acquisition technique called PRO-QUEST was translated and optimized for a 3T clinical scanner based on a 3D readout. The aim of this technique is to quantify CEST parameters based on signal acquisition during the approach of the magnetization towards steady-state. Modifications of the technique were suggested to correct for the enhanced direct saturation effect at lower field strengths. The methods were evaluated and compared based on measurements of healthy human volunteers.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kujawa, Aaron Sarwar
Contributors dc:contributor
  • Golay, X
  • Punwani, S

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10096899/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Kujawa, Aaron Sarwar. Quantification aspects of chemical exchange saturation transfer MRI. Doctoral thesis, UCL (University College London), 2020. https://discovery.ucl.ac.uk/id/eprint/10096899/