dc:description.abstractMost future scenarios for decarbonising the UK energy system include a high proportion of homes with electric heat pumps. Shifting current heating demand patterns to the electricity network would increase peak demands. Demand management to reduce this peak can only be achieved if households are prepared to accept flexible running times for their central heating. This thesis investigates what this flexibility looks like from the perspective of the households involved. The investigation centres on a case study of a trial of hybrid heat pumps (gas boiler and air source heat pump) with smart controllers. The algorithmic controllers aim to satisfy both household requirements for warmth and energy network requirements for flexible demand. A practice theory approach is used to assess design assumptions about what residents want from their heating and how they interact with the controls. Household requirements are frequently more complex than achieving steady temperatures when the home is occupied. The thermal conditions considered appropriate vary with different activities. In many of the case study homes residents preferred different temperatures at different times of day. A desire for cool bedrooms may limit the potential for preheating during the night ahead of morning peak demand periods. Residents are concerned not only with temperature but also the running pattern of the heating. Some households noticed unwelcome consequences of changed running patterns (for example, noise at night time) and in some instances the residents did not understand how to adjust control settings to achieve their preferred response. High levels of manual operation were seen in some homes. A few households were frequently altering setpoints to stop or start the heating, rather than relying on automated, pre-scheduled settings. This mode of operation limits the potential for demand management based on predictable, scheduled heating operation.
Degree
thesis:*- Level dc:type.qualificationlevel
- Doctoral
- Grantor dc:publisher.institution
- UCL (University College London)
- Year dc:date.issued
- 2020
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hanmer, Clare
Rights
- Language dc:language
- en, eng
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- https://discovery.ucl.ac.uk/id/eprint/10097492/