Back to search

UCL (University College London)

In vitro Tools for the Personalised Haemodynamic Assessment of Aortic Dissection

Abstract

dc:description.abstract

Diagnosis, management and treatment remain a challenge for Aortic Dissection (AD) because it is a highly patient specific pathology. Clinical practice still relies primarily on crude markers that cannot fully capture the complex haemodynamic features of AD and reliably predict dissection propagation or rupture. Whereas in vitro models would allow for the accurate study of AD flow fields in physical phantoms, they are currently scarce and almost exclusively rely on over simplifying assumptions. The aim of this thesis was to develop an experimental framework for patient-specific in vitro models of AD, in order to help clinical decision making, support the development of numerical methods and test medical devices. A novel mock circulatory loop was designed and developed. It comprises a computer controlled pulsatile pump system, tunable afterload models to reproduce the downstream vasculature and a patient-specific AD phantom. The platform was coupled with mathematical models informed by non-invasive clinical data and was tuned to reproduce a patient-specific case study. The complex haemodynamics reproduced by the platform was characterised by flow rate and pressure acquisitions as well as Particle Image Velocimetry (PIV) derived velocity fields. The pressure and flow rate data measured at the outlets of the AD phantom showed good agreement with both the available clinical data and in silico simulations. Aortic haemodynamics analysis revealed complex flow patterns,including flow reversal, recirculation regions and stagnant flow in the false lumen. Applying Proper Orthogonal Decomposition to PIV data demonstrated that reduced order modelling could be used for the development of computationally efficient in silico AD models. The contributions made in this thesis represent a significant advancement to the state of the art of AD in vitro modelling. There is currently no in vitro platform capable of reproducing patient-specific flows tuned by non-invasive clinical data. The framework that uses in vitro, in silico and in vivo data opens up new possibilities for the development of novel surgical procedures and devices to tackle AD. Ultimately, applying the methods developed in this thesis has the potential to improve the outcome of patients affected by AD.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Franzetti, Gaia

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10106265/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Franzetti, Gaia. In vitro Tools for the Personalised Haemodynamic Assessment of Aortic Dissection. Doctoral thesis, UCL (University College London), 2020. https://discovery.ucl.ac.uk/id/eprint/10106265/