Back to search

UCL (University College London)

Hand-eye calibration, constraints and source synchronisation for robotic-assisted minimally invasive surgery

Abstract

dc:description.abstract

In robotic-assisted minimally invasive surgery (RMIS), the robotic system allows surgeons to remotely control articulated instruments to perform surgical interventions and introduces a potential to implement computer-assisted interventions (CAI). However, the information in the camera must be correctly transformed into the robot coordinate as its movement is controlled by the robot kinematic. Therefore, determining the rigid transformation connecting the coordinates is necessary. Such process is called hand-eye calibration. One of the challenges in solving the hand-eye problem in the RMIS setup is data asynchronicity, which occurs when tracking equipments are integrated into a robotic system and create temporal misalignment. For the calibration itself, noise in the robot and camera motions can be propagated to the calibrated result and as a result of a limited motion range, the error cannot be fully suppressed. Finally, the calibration procedure must be adaptive and simple so a disruption in a surgical workflow is minimal since any change in the setup may require another calibration procedure. We propose solutions to deal with the asynchronicity, noise sensitivity, and a limited motion range. We also propose a potential to use a surgical instrument as the calibration target to reduce the complexity in the calibration procedure. The proposed algorithms are validated through extensive experiments with synthetic and real data from the da Vinci Research Kit and the KUKA robot arms. The calibration performance is compared with existing hand-eye algorithms and it shows promising results. Although the calibration using a surgical instrument as the calibration target still requires a further development, results indicate that the proposed methods increase the calibration performance, and contribute to finding an optimal solution to the hand-eye problem in robotic surgery.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pachtrachai, Krittin

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10113933/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Pachtrachai, Krittin. Hand-eye calibration, constraints and source synchronisation for robotic-assisted minimally invasive surgery. Doctoral thesis, UCL (University College London), 2020. https://discovery.ucl.ac.uk/id/eprint/10113933/