Back to search

UCL (University College London)

A novel approach to monitor tissue oxygen saturation with broadband near-infrared spectroscopy

Abstract

dc:description.abstract

Cerebral oximetry is the measurement of tissue oxygen saturation, StO2, with near-infrared spectroscopy (NIRS). The technique offers a non-invasive assessment of cerebral oxygenation and has potential to be used as a biomarker in neonatal critical care, particularly hypoxic-ischaemic-encephalopathy (HIE). HIE is a major cause of neonatal mortality and affected neonates need continuous cerebral monitoring to guide treatment and improve patient outcome. While multiple algorithms to recover StO2 have been published, issues with low measurement accuracy or extracranial tissue signal contamination remain. This thesis is focused on the exploration of recovering StO2 from continuous-wave broadband NIRS measurements with the aim to develop a novel algorithm to recover StO2 with increased dynamic range and depth resolution. The novel algorithm, broadband multidistance oximetry (BRUNO), recovers StO2 from a broadband multidistance measurement of the attenuation slope against distance. BRUNO combines and expands two other StO2 algorithms, spatially resolved spectroscopy (SRS) and broadband fitting (BF). The evaluation of algorithm performance was done in data obtained in computational simulations and phantoms. The median error of brain StO2 recovered in simulations of brain and extracerebral tissue oxygenation changes was 1.1% with BRUNO, 2.3% with BF and 3.8% with SRS. Measurements during full oxygenation-deoxygenation cycles in a homogeneous blood phantom showed differences in the dynamic range of the algorithms; BRUNO recovered StO2 over 0–100%, BF over 0–90% and SRS over 40–80%. These results show higher accuracy of BRUNO StO2, higher sensitivity to brain oxygenation and wider dynamic range. Measurements of StO2 in one neonate with HIE showed that the StO2 algorithms led to different baseline values. Including an automated data assessment step in BRUNO to evaluate the suitability of collected spectra for analysis ensured BRUNO reliability. These findings highlight the effect of StO2 algorithm selection on oxygenation recovery; applying BRUNO in the clinical care setting could reveal further insight into complex oxygenation processes occurring during neonatal brain injury.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kovacsova, Zuzana

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10115224/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Kovacsova, Zuzana. A novel approach to monitor tissue oxygen saturation with broadband near-infrared spectroscopy. Doctoral thesis, UCL (University College London), 2020. https://discovery.ucl.ac.uk/id/eprint/10115224/