Ventilation in occupied homes: measurement, performance and sociotechnical perspectives

Abstract

dc:description.abstract

In the UK, steps have been taken to reduce air permeability of buildings and reduce their energy consumption due to unplanned ventilation. However, adequate ventilation is required for good indoor air quality. The building regulations require means for adequate ventilation in new buildings for good indoor air quality, and in England Approved Document F (ADF) sets out how this may be achieved. Nonetheless, few detailed studies of ventilation in occupied homes have been carried out. This project addresses aspects of ventilation measurement, performance of ventilation systems and the sociotechnical nature of ventilation in occupied homes. Ventilation in occupied buildings is driven by building characteristics, ventilation equipment, weather conditions and occupant actions and therefore can be highly variable. Despite this, much ventilation research in occupied homes either measures a long-term average ventilation rate or collects a small number of `snap-shot’ measurements of ventilation rate. This research developed a method for measuring ventilation rates in occupied homes based on the tracer gas decay technique using metabolic CO₂. The method was applied in four occupied dwellings over 6 months to give more than 500 ventilation rate measurements. These results facilitated assessment of the performance of the ventilation system and exploration of the variation in ventilation rates. This revealed significant differences in the ventilation rates experienced by occupants in the different dwellings and highlighted shortcomings in the planned ventilation system. Ventilation in occupied homes is strongly influenced by occupants. The final part of the research used a social practice theory framework to compare the participants’ practices with the intended uses of ventilation equipment implicit in ADF. This revealed that although the participants shared many of ADF’s goals in terms of the air in their homes, their practices were more nuanced than ADF and that their use of the ventilation equipment did not reflect ADF’s intentions.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Few, Jessica Frances Mary
Contributors dc:contributor
  • Elwell, C
  • Shipworth, M

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10130632/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Few, Jessica Frances Mary. Ventilation in occupied homes: measurement, performance and sociotechnical perspectives. Doctoral thesis, UCL (University College London), 2021. https://discovery.ucl.ac.uk/id/eprint/10130632/