Evaluating energy and indoor air quality potential impact of spray foam: a case study of robotic application

Abstract

dc:description.abstract

Homes in the UK require transformational retrofit to meet Net Zero legislation. Selecting the right insulation balances multiple, often clashing, performance criteria: energy savings, capital cost, thermal comfort, installation disruption, heritage impact and indoor air quality. There is a lack of evidence in balancing trade-offs between energy, heritage and indoor air quality impact when comparing insulation products. This thesis converged data from different disciplines and showed the retrofit potential, key barriers and enablers of insulating millions uninsulated floors in the UK. In underfloor voids with limited space polyurethane spray foam applied with robots offers better insulating potential compared to conventional products with the same thickness, however more scientific evidence was needed on off-gassing emissions. To measure spray foam emissions, heritage science techniques were adopted to develop a novel method. The method could be applied in built environment case studies to measure volatile organic compounds (VOC) from polyurethane products. The VOC emissions during spraying were assessed for a majority of spray foam product available on the open market. The original data provided evidence for generating a new hypothesis for why 1,2-dichloropropane (1,2-DCP) was found in spray foams. The data suggests 1,2-DCP may have been part of some of the raw materials contrary to the existing hypothesis from 2003 suggesting it was a result of flame retardants degradation. This is relevant as 1,2-DCP was re-classified as Class 1 carcinogen in 2014. Furthermore, ventilation strategies and their effectiveness as a mitigation measure for reducing VOCs were evaluated. Spray foam VOC concentrations were first measured in controlled conditions. Experimental data revealed that VOC concentrations are significantly lower next to sprayers when robots and robust ventilation are deployed. The findings were validated in a case study where long-term VOC concentrations were measured for a period of up to 2 months after retrofit. The majority of VOC concentrations were not detected indoors post-installation with the exception of flame retardants.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Naldzhiev, Dzhordzhio

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10175544/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Naldzhiev, Dzhordzhio. Evaluating energy and indoor air quality potential impact of spray foam: a case study of robotic application. Doctoral thesis, UCL (University College London), 2023. https://discovery.ucl.ac.uk/id/eprint/10175544/