Back to search

UCL (University College London)

The use of 3D-CT Planning and Patient Specific Instrumentation in Total Hip Arthroplasty: Pre-, Intra- and Post-Operative Evaluation

Abstract

dc:description.abstract

Optimal implant placement in Primary Total Hip Arthroplasty (THA) aims to restore physiological hip function. Three-Dimensional Computed-Tomography (3D-CT) and Patient-Specific Instrumentation (PSI) can guide implant positioning in THA. Despite growing evidence of preferable results compared to conventional templating, these tools remain underused in clinical practice. This thesis aimed to assess the role of 3D-CT planning and PSI in terms of femoral stem implantation through pre- and post-operative 3D-CT image analysis in primary THA. 3D-CT planning accurately predicted the femoral stem size (96% within one size) and femoral offsets in uncemented THA. Predicting Prosthetic Femoral Version (PFV) proved to be the unmet need given the limited surgical control of uncemented femoral stems to avoid an insufficient or retroverted PFV associated with THA instability. An insufficient PFV (<5°) was reported in 20% of the femoral stems. The malleable nature of cement in cemented fixation offers increased control and can avoid delivering an insufficient PFV. All cases in a cemented THA group were anteverted more than 5°. However, both uncemented and cemented THA reported high PFV variability, indicating the need to develop PSI to guide PFV. First, the accuracy of a PSI osteotomy guide was evaluated by aligning pre- and postoperative 3D-CT reconstructed osteotomy levels to quantify their relative discrepancy, proving that planned neck osteotomy was delivered within the clinically accepted 5mm in 96% of cases. Finally, a pilot study was conducted to evaluate whether a PSI guide, engineered to indicate the angle at which the stem was positioned intra-operatively, can achieve the target range of PFV. Post-operative CT measurements suggested its efficacy in achieving a lower variability of PFV, when compared to the non-guided THA. These findings will inform that planning software cannot predict PFV in uncemented THA and highlight the potential of PSI in delivering the intended PFV in cemented THA.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Moralidou, Maria

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10179517/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Moralidou, Maria. The use of 3D-CT Planning and Patient Specific Instrumentation in Total Hip Arthroplasty: Pre-, Intra- and Post-Operative Evaluation. Doctoral thesis, UCL (University College London), 2023. https://discovery.ucl.ac.uk/id/eprint/10179517/