Back to search

UCL (University College London)

Strain imaging using multimodal X-ray imaging

Abstract

dc:description.abstract

X-ray strain imaging uses X-ray tomography to visualise internal deformations in loaded samples, with strain measured via digital volume correlation. While effective for highly absorbing materials, strain measurements of low-absorbing materials like soft tissues and polymers become ineffective due to reduced contrast-to-noise ratio, limiting precision and resolution. Phase contrast tomography, using synchrotrons or micro-focus X-ray systems, shows promise but is often inaccessible or limited by a small field of view. In this thesis X-ray strain imaging with two phase contrast methods—edge illumination and two-dimensional beam tracking—compatible with compact X-ray sources up to 100 μm focal spot size is investigated. For edge illumination a molybdenum source is operated at 17.5 keV mean energy, while for two-dimensional beam tracking a tungsten source is operated at 15 keV mean energy. These techniques provide absorption, refraction, and scattering contrast, enhancing resolution without increasing geometric magnification, preserving a larger field of view. The strain retrieval precision is analysed using digital volume correlation across contrast types, sampling conditions, and scanning methods. For edge illumination at 0.5 mm strain spatial resolution, absorption contrast achieves a strain precision of 0.5 × 10−3 for a polymer foam and 1.3 × 10−3 for ethanol-fixed tissue, while phase contrast is less precise (12 × 10−3 for foam, 55 × 10−3 for tissue). For two-dimensional beam tracking at 0.45 mm strain spatial resolution, absorption achieves 0.6 × 10−3 (foam) and 1.7 × 10−3 (tissue), while phase contrast reaches 1.2 × 10−3 (foam) and 6.1 × 10−3 (tissue). In this thesis, two applications are examined: a biomedical study on tumour margin detection using a mechanically realistic phantom with a 3.2 kPa matrix and a 13.9 kPa stiff inclusion, and an industrial study characterising the mechanical deformation of polymer bead foam. The inclusion is identified through the strain field and validated with finite element analysis. Additionally, the potential for inherent strain imaging by using the scattering signal is explored.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Peiffer, Carlo
Contributors dc:contributor
  • Munro, Peter
  • Olivo, Sandro

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10206163/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Peiffer, Carlo. Strain imaging using multimodal X-ray imaging. Doctoral thesis, UCL (University College London), 2025. https://discovery.ucl.ac.uk/id/eprint/10206163/