Back to search

UCL (University College London)

Total performance of UK Passivhaus primary schools

Abstract

dc:description.abstract

The urgent need to mitigate and adapt to climate change in the UK’s built environment has increased emphasis on delivering low-energy and net-zero carbon aligned school buildings that also ensure high standards of indoor environmental quality and resilience to future climatic conditions. Passivhaus can be understood as one implementation pathway towards these objectives, through enhanced thermal insulation, airtight construction and controlled ventilation strategies. While the Passivhaus standard is increasingly adopted to meet tightening energy efficiency standards, there remains a lack of comprehensive evidence of in-use energy and indoor environmental quality performance in schools. This thesis addresses this knowledge and evidence gap by delivering the first comprehensive multi-case evaluation of Passivhaus-certified primary schools in the UK. It investigates energy use, ventilation, indoor thermal conditions and air quality, based on one year of high spatiotemporal resolution monitoring of indoor air temperature, relative humidity, CO2, PM2.5, PM10, NO2, and TVOCs, in twelve classrooms across four schools in England and Wales. Seasonal investigations included passive VOC sampling, occupancy tracking, and user surveys. Statistical modelling was carried out to quantify the influence of key determinants on indoor thermal conditions and air quality in Passivhaus schools, using linear mixed-effects models. Dynamic thermal modelling was used to evaluate future overheating risk in a London-based school, using standardised weather files. Key findings show that UK Passivhaus primary schools: Use 81% less fossil thermal energy and marginally less electricity than mechanically ventilated schools in England and in Wales; Provide higher ventilation rates than those reported in UK studies; Achieve 33% lower PM2.5 infiltration than baseline schools in winter; Demonstrate improved indoor air quality, with health-relevant index scores 47-64% lower than benchmarks; Exhibit greater thermal resilience with indoor temperatures 50% less sensitive to outdoor fluctuations and more responsive to ventilation rates; Overheating risk was identified in a case study Passivhaus school in London, which may require cooling in the near future (50% probability under 2020s high emissions scenario), with cooling demand surpassing the heating demand within the building’s life span. Statistical analysis found that ventilation strategy, classroom volume, surface materials and the presence of direct outdoor access were key determinants of building performance, with implications for thermal conditions, heating demand, dilution of indoor air pollutants and potential infiltration of outdoor particulates. Indoor VOC concentrations were influenced by both primary indoor sources and secondary formation (e.g., 2-ethylhexanol from phthalate degradation). Elevated levels of formaldehyde were linked to increased temperature and ventilation rates in terpene-rich environments. Prioritising the Passivhaus standard, particularly in polluted and socio-economically deprived areas, can reduce inequalities in children’s environmental exposures but focused guidance can help avoid past mistakes that result in poor building performance. The findings of this PhD informed the development of a new decision-support framework to help guide specification, design, and evaluation of Passivhaus primary schools, in the UK, presented in the context of this thesis.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Thoua, Chrysoula

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10227590/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Thoua, Chrysoula. Total performance of UK Passivhaus primary schools. Doctoral thesis, UCL (University College London), 2026. https://discovery.ucl.ac.uk/id/eprint/10227590/