Back to search

UCL (University College London)

Exploring Parameter Variation in Cochlear Implant Fitting to Improve Speech Perception in Difficult Listening Conditions

Abstract

dc:description.abstract

Cochlear Implantation (CI) constitutes the default treatment for hearing loss where limited benefit is provided by conventional amplification. Despite improvement in technology, surgical technique, rehabilitation and patient selection, there remains large variability in hearing outcomes achieved by users. Within this variability, an influential factor is the setting of adjustable parameters. The thesis aim was to evaluate the mapping of two key parameters on the ability of adult users to detect fundamental cues to speech, speech in quiet and in noise at soft intensity level, with a view to providing clinical recommendation. A systematic review was conducted to review adjustment to input dynamic range (IDR), electrical threshold T level and rate of stimulation on speech perception ability. A limited understanding of the influence of parameter adjustment on soft intensity level speech, upon fundamental cues for speech and of knowledge regarding interaction was found. A pilot study assessed the efficacy of an amplitude modulation difference task (AM) assessing temporal cues an intensity difference limen (IDL) task assessing amplitude cues presented at soft intensity level; this also informed the sample size for a main trial. The main trial indicated T level setting to have a significant effect on spectral temporally modulated ripple (SMRT) test, assessing spectral cues, AM and detection of monosyllables in quiet. T level setting and electrical stimulation rate had a significant effect on AM discrimination. Significant interaction between T level setting and electrical dynamic range existed for SMRT, continuous discourse tracking (CDT) and monosyllables in quiet; interaction was complex and non-uniform negating simple clinical recommendation. These findings demonstrate the importance of bespoke T level setting and provide guidance for T level and rate setting to improve AM discrimination. Interactions should be given consideration however individualised mapping is a requirement to optimise perception of speech cues and speech in quiet conditions and at soft intensity level.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nunn, Terry

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10227654/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Nunn, Terry. Exploring Parameter Variation in Cochlear Implant Fitting to Improve Speech Perception in Difficult Listening Conditions. Doctoral thesis, UCL (University College London), 2026. https://discovery.ucl.ac.uk/id/eprint/10227654/