Back to search

UCL (University College London)

Development and Evaluation of a Wavelength Modulated Near-Infrared Spectroscopy System

Abstract

dc:description.abstract

Near-infrared spectroscopy (NIRS) is a diagnostic method used to estimate changes in oxy- and deoxy-haemoglobin concentrations in biological tissue from variations in near-infrared diffuse reflectance measurements. However, conventional diffuse reflectance measurements are highly sensitive to variations in optical coupling on the skin surface. An alternative approach has been proposed, known as wavelength modulated NIRS (WM-NIRS), where the source wavelength is modulated at a fixed frequency. Variation in the tissue absorption over the wavelength range will result in a small modulation in detected intensity which can be measured using lock-in or Fourier methods. WM-NIRS is based on two key hypotheses: first, that the ratio of modulation amplitude to average detected intensity is independent of coupling; and second, that such measurements may enable the determination of absolute concentrations of tissue absorbers. This project involved the development and comprehensive system characterisation of a WM-NIRS system based on a supercontinuum laser and an acousto-optic tuneable filter. System evaluation identified wavelength-dependent effects and measurement limitations, informing targeted hardware and software improvements as well as the development of a calibration algorithm. Experimental results validated the first hypothesis, demonstrating that the measured signal ratio is largely insensitive to coupling variations. Quantitative measurements were subsequently performed using well-characterised absorbing dyes, both with and without scattering media, to investigate the feasibility of determining absolute chromophore concentrations. The results demonstrate that the final system is capable of producing reliable, interpretable, and quantitatively meaningful measurements. Investigation of the second hypothesis was limited by an observed scaling error that was not consistently present across all experiments, as well as by the inability to perform measurements involving multiple absorbers and scattering media, primarily due to the instability of the available near-infrared dyes. While there were limitations in the investigation towards determining absolute concentrations, the findings highlight both the potential of WM-NIRS and the practical challenges that must be addressed in future work.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pacis, Danica Mitch M.
Contributors dc:contributor
  • Hebden, Jem
  • Gibson, adam

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10231226/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Pacis, Danica Mitch M.. Development and Evaluation of a Wavelength Modulated Near-Infrared Spectroscopy System. Doctoral thesis, UCL (University College London), 2026. https://discovery.ucl.ac.uk/id/eprint/10231226/