UCL (University College London)
The Characterization of Epileptic Generators Based on the Quantitative Analysis of Interictal Epileptiform Discharges (IED) Recorded During icEEG-fMRI
Abstract
dc:description.abstractBackground: Pre-surgical evaluation of drug-resistant focal epilepsy requires precise local-isation of the epileptogenic zone. Concurrent intracranial EEG–fMRI (icEEG-fMRI) pro-vides this by mapping the haemodynamic correlates of interictal epileptiform discharges (IEDs). The established approach classifies IEDs using Wave_clus (Sharma et al., 2017, 2019), assigning every discharge to exactly one class. IEDs vary continuously in morpholo-gy, however, and a single discharge is not always cleanly assignable. We test whether fuzzy classification of IEDs, which represents waveform variability through partial cluster mem-bership, changes the concordance of the resulting BOLD maps with the surgically resected zone, relative to the Wave_clus baseline, and we compare three fuzzy clustering algorithms against one another. Concordance is scored categorically using the scheme of Chaudhary et al. (2021). Data and Methods: We re-analysed icEEG-fMRI data from eight patients with drug-resistant focal epilepsy, seven of whom achieved ILAE class 1 outcome after resective sur-gery; the eighth (P5) achieved ILAE class 4 and was retained as a contrasting case in which the resected volume cannot be assumed to coincide with the full extent of the EZ. IEDs were segmented into 300 ms epochs and entered into a pipeline combining Dynamic Time Warp-ing, Classical Multidimensional Scaling, and three fuzzy clustering algorithms applied in parallel: Fuzzy C-Means (FCM), Gath-Geva (GG) and Gustafson-Kessel (GK), differing in their geometric assumptions about cluster shape. The embedding dimension and cluster number were selected using the Xie–Beni validity index, a standard measure of fuzzy-clustering quality that balances cluster compactness against separation. The pipeline was first validated on synthetic data of known structure. A NULL control simulation, in which waveforms were drawn from Gaussian noise with no cluster structure, confirmed pipeline specificity, and a three-template simulation, in which waveforms were generated from three known morphologies under controlled noise, confirmed sensitivity, recovering the correct cluster number and achieving near-perfect mapped accuracy at noise levels up to σ = 0.5. The two simulations together established an operating envelope of at least 30 IEDs per clus-ter and σ ≤ 0.5, together with validity-index thresholds (< 0.25 for structured data, > 0.50 for unstructured) applicable to real recordings without ground truth. For each patient we constructed seven general linear models: one based on Wave_clus, three on hard-classified fuzzy clusters, and three on membership-weighted fuzzy regressors. Because fuzzy mem-berships sum to one across clusters, the membership-weighted regressors were convolved with the canonical haemodynamic response function and its temporal and dispersion deriva-tives outside SPM and entered as ordinary regressors, bypassing the orthogonalisation step that would otherwise collapse the rank of the design matrix. Concordance with the surgical resection volume was assessed using the four-level scheme of Chaudhary et al. (2021). Results: The three fuzzy algorithms were first compared head-to-head on the same eight patients using a membership-confidence metric, defined as the proportion of IEDs whose maximum membership across clusters reached at least 0.7. Gustafson-Kessel produced the highest membership confidence in seven of eight patients, with mean confidence 68% across the cohort against 61% for FCM and 61% for GG. The fuzzy partitions and the Wave_clus baseline agreed on the number of clusters in three patients and differed in the remaining five. The three fuzzy algorithms partitioned the same IED feature space into dif-ferent clusters and produced different BOLD maps in most patients. Hard and fuzzy-weighted variants of the same algorithm converged when membership was sharply bimodal and diverged when it was graded. Conclusion: Across the cohort, the fuzzy approaches showed lower concordance with the resected zone than the Wave_clus baseline in most patients. Concordance was not uniform, however: in a minority of patients the fuzzy partitions recovered concordance the baseline had missed, most notably P6, while in others they lost concordance the baseline had cap-tured. The central finding is that the localisation of IED-related BOLD activity depends on choices made at the classification stage that the Wave_clus baseline does not expose, and that these choices are visible only under a model-comparison framework of the kind devel-oped here.
Degree
thesis:*- Level dc:type.qualificationlevel
- Doctoral
- Grantor dc:publisher.institution
- UCL (University College London)
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Aldakhil, Hajar
- Contributors dc:contributor
-
- Lemieux, Louis
- Diehl, Beate
- Wang, Yujiang
Rights
- Language dc:language
- en, eng
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- https://discovery.ucl.ac.uk/id/eprint/10232106/