Back to search

UCL (University College London)

Comparative Assessment Between Renewal MI and Other Experimental Formulations

Abstract

dc:description.abstract

Background: Dental caries is considered a chronic disease with a major impact on economic and clinical management in paediatric dentistry. Resin-modified glass ionomer (RMGI), such as Fuji II light cure (Fuji II LC), presents limitations, as evidenced by long-term performance in mechanical durability and bioactivity. The renewal MI composite (RMI composite) was designed to be a self-adhesive material that does not require caries removal, while also acting as an antibacterial agent and remineralising the affected enamel and dentine. Statement of Problem: The RMI composite exhibited significant limitations, including lower mechanical properties and limited long-term retention in a phase II clinical trial. Monocalcium phosphate monohydrate (MCPM) and polylysine (PLS) reduce the mechanical properties of RMI due to increased water absorption and also lower the surrounding pH. This study replaces MCPM with calcium oxide (CaO), which can react with absorbed water, increasing pH. Methodology: The control groups for the entire study were Fuji II LC, RMI paste, and paste with glasses only (P0). There were 4 experimental groups, with different concentrations of PLS (8 or 4 wt%) and CaO (16 or 8 wt%). Fourier Transform Infrared Spectroscopy (FTIR) was used to confirm chemical groups present in each raw material and to compare newly formed pastes with aged ones. Biaxial flexural strength (BFS) was assessed at 0, 7 days, 1 month, 3 months and 1 year. pH and calcium content of sample storage solutions were determined. Two-way, and threeway ANOVAs were used in the statistical analysis, followed by post hoc multiple-comparison tests. Results: FTIR spectra were consistent with known chemical structures. Final monomer conversions ranged between 74-83% for fresh pastes and 82-87% for aged pastes. Increasing CaO and PLS both reduced strengths but increased calcium ion release. Replacing MCPM in RMI with the same mass of CaO however, led to strength at 1 year increasing from 62 to 103 MPa. It additionally increased pH at 1 month from 3 to 10 and raised early calcium release. Conclusion: New formulations with CaO instead of MCPM show promising mechanical and ion release properties that may potentially address the limitations of Renewal MI detected in a phase II clinical trial.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Khayat, Arwa Abdulaziz

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/10232841/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Khayat, Arwa Abdulaziz. Comparative Assessment Between Renewal MI and Other Experimental Formulations. Doctoral thesis, UCL (University College London), 2026. https://discovery.ucl.ac.uk/id/eprint/10232841/