Back to search

UCL (University College London)

Optimisation of the acousto optic signal detection for biomedical applications

Abstract

dc:description.abstract

Near infrared light has been widely used to probe human tissue oxygenation non-invasively. However the highly scattering nature of tissue limits light penetration depths and optical measurement is more sensitive to optical changes in the superficial region (SFR) of tissue. It is proposed that the penetration depth and the localisation of the optical measurement can be improved by the Acousto-Optic (AO) method. The AO method tags diffuse photons in an optically tissue mimicking medium by using focused ultrasound waves. Generally it is believed that the region probed by the AO method is decided by the position of the focused ultrasound region (FUR). Therefore the AO method can potentially improve the penetration depth and reduce the susceptibility in the SFR of the optical measurement by relocating the FUR to deeper region in tissue. The spatial sensitivity of the AO measurement is mapped and compared to the spatial sensitivity of the optical measurement experimentally. The AO method can monitor absorption and scattering changes in deeper regions than the optical measurement. The AO method is less affected by the optical changes in the SFR. The most sensitive region probed by the AO method can be relocated by re-positioning the FUR. But it does not always coincide with the FUR. The AO spatial sensitivity depends on the overlap of the FUR and the photon path distribution. This overlap region affects the AO signal differently for absorption and scattering changes. Thus, concurrent monitoring of absorption and scattering changes require careful positioning of the FUR. Finally, it is also demonstrated that the pulsed-wave ultrasound can be used with the AO method in a cylindrical geometry. An optimal optodes’ positions for the AO signal detection can be predicted experimentally for a given location of the FUR within a cylindrical geometry.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gunadi, S.

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1335823/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Gunadi, S.. Optimisation of the acousto optic signal detection for biomedical applications. Doctoral thesis, UCL (University College London), 2011. https://discovery.ucl.ac.uk/id/eprint/1335823/