Relationships between floc properties and NOM removal using a moorland water source

Abstract

dc:description.abstract

Natural organic matter, or NOM presents a treatment challenge to the conventional water treatment process and has been associated with the formation of disinfection by-products (DBP’s) such as Tri-halomethanes (THM’s) if not removed prior to the disinfection stage. Poor removal of NOM is also thought to lead to filter performance problems such as turbidity or particle count breakthrough, which represents an increased risk of passage of Cryptosporidium into the treated water. Understanding the complex nature of NOM floc and how its physico-chemical properties relate to the coagulation matrix within the water treatment process is therefore key to optimising NOM removal. This forms the basis of the study which was carried out entirely using a natural raw moorland source water, which is preferable over synthetic kaolin based systems. The experimental programme encompassed both bench-scale and pilot-scale tests, and investigated the effect of changes to a number of variables such as coagulant type, coagulation pH and Fe:DOC ratio on floc physico-chemical properties. The approach taken in this work, of monitoring NOM removal alongside floc properties obtained from the optical flocculation monitor revealed some key trends. Firstly under equivalent shear conditions the coagulant dose almost always correlated with the steady-state maximum floc size, and influenced the flocculation rate. Generally the ferric based systems with the largest and fastest forming floc correlated with the best NOM removal, but when the applied Fe:DOC range was narrow and within an optimal range it was difficult to pin-point the best dose. The organic coagulants polyDADMAC and Zetag 64 formed larger, amd more reversible floc than the ferric based systems but with poor NOM removal. Secondly under equivalent shear conditions the larger flocs exhibited the least resistance to breakage, regardless of the coagulant system. Finally with regard to floc physico-chemical properties and filter performance, some key trends were revealed. Zeta potential influenced both NOM removal and the filtered water quality with considerable improvement noted as the charge tended towards 0 mV, and poor performance in the form of breakthrough as the charge decreased to <-10 mV or >4 mV. Flocculant dosing prior to filtration increased floc reformation and prevented breakthrough when charge destabilisation was sub-optimal, and could prove a useful strategy to employ when experiencing challenging winter conditions.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Balls, Margaret

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1417138/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Balls, Margaret. Relationships between floc properties and NOM removal using a moorland water source. Doctoral thesis, UCL (University College London), 2014. https://discovery.ucl.ac.uk/id/eprint/1417138/