Back to search

University of London

Plasmid DNA and bacterial artificial chromosomes processing for gene therapy and vaccination: studies on membrane sterile filtration.

Abstract

dc:description.abstract

Plasmids currently applied in clinical trials are generally < 20 kb, but the interest in larger circular vectors is rising. However, due to their size and character, filterability and irreversible damage intensified by elongational shear are major concerns during a sterilising filtration procedure. Therefore, key parameters affecting the normal-flow membrane filtration performance of solutions containing purified plasmid DNA and bacterial artificial chromosomes were investigated in this study. Two small scale filtration systems were designed to enable information on material properties to be obtained. Firstly, a pressure driven syringe system was used to conduct constant flux experiments. Data on transmission and degradation could be obtained rapidly and only required small sample volumes (< 1 mL). Secondly, a positive pressure filtration system which permitted operations at constant transmembrane pressure had been applied to determine the filter capacity, this information is useful to facilitate the scale-up of a membrane filtration process. The results showed transmission of DNA vectors decreased linearly with molecular size (6-1 16 kb) and confocal microscopy images confirmed that a fraction of the DNA molecules were being retained by the membrane filters. Degradation increased with molecular weight, flux and number of filtration passes for vectors > 20 kb. The filtration performance was affected by the membrane type used and could be improved by addition of NaCl in the formulation buffer. For filtrations performed at constant pressure, permeate flow decayed with time. As predicted from controlled flux experiments, transmission decreased with increasing molecule size. Initial permeate flux was affected by vector size, DNA concentration and operating pressure. Increase in plasmid size and operating pressure led to reduced membrane capacities. The small scale membrane (filtration area = 1 cm2) capacity was used successfully to predict the performance of a larger scale filtration (filtration area = 4 cm2).

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of London
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kong, S.Y.

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1444899/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Kong, S.Y.. Plasmid DNA and bacterial artificial chromosomes processing for gene therapy and vaccination: studies on membrane sterile filtration.. Doctoral thesis, University of London, 2007. https://discovery.ucl.ac.uk/id/eprint/1444899/