Back to search

UCL (University College London)

To Develop Techniques that will Enhance Dermal Cell and Tissue Attachment in Order to Create a Seal and Prevent Infection of Implant Biomaterials used for ITAP

Abstract

dc:description.abstract

Failure modalities of bone anchoring and skin penetrating devices, such as Intraosseous Transcutaneous Amputation Prosthesis (ITAP), stem from the lack of dermal cell and tissue attachment at the skin implant interface. As a result the implant shaft offers a direct route for harmful pathogens into the body. The aim of my thesis is to develop techniques that will enhance dermal cell and tissue attachment, in order to create a tight biological seal of implant biomaterials currently used for ITAP. I compared the effects of fibronectin against its cell binding region- a 3-amino- acid region know as Arginine-Glycine-Aspartic Acid (RGD)- on human dermal fibroblast (HDF) attachment to ITAP substrates. Silanization of RGD- polypeptides provided a durable biological functionalisation technique that significantly increased HDF attachment compared with controls. No significant difference was observed between fibronectin and RGD-polypeptide functionalised substrates in vitro. I then investigated the effects of porosity (as a function of pore and strut diameter) on soft fibrosis tissue in-growth and vascularisation. Electron Beam Manufacturing (EBM) provided an effective method of creating precise 3- dimensional porous structures. Porosity as a function of pore and strut diameter led to optimal soft fibrosis tissue in-growth with 700μm pore and 300μm strut diameters exhibiting significantly increased vascularisation over other implants groups after 4 weeks in vivo. The development of these functionalisation techniques, which utilised porous structures and silanization of RGD sequences, were combined and applied to the ITAP device. An EBM porous flange, of 700μm pore and 300μm strut diameters, were silanised with RGD-polypeptide and compared with the current clinical standard ITAP device. Implants were tested in a trans-tibial, transcutaneous ovine model for 5-months. Functionalisation techniques employed in this study did not eradicate the failure modalities of ITAP devices, however they did not detrimentally affect the formation of a stable transcutaneous interface compared with current clinical standards. Significant positive effects were observed, with the biological functionalisation, using silanised RGD-polypeptides, significantly increasing dermal tissue infiltration and porous structures, manufactured by EBM, significantly increasing vascularisation. Functionalisation with silanised RGD-polypeptides to porous structures may provide an opportunity to enhance the skin implant interface and tight biological seal for bone anchoring and skin penetrating devices, such as ITAP, clinically.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dowling, RP

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1461121/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Dowling, RP. To Develop Techniques that will Enhance Dermal Cell and Tissue Attachment in Order to Create a Seal and Prevent Infection of Implant Biomaterials used for ITAP. Doctoral thesis, UCL (University College London), 2015. https://discovery.ucl.ac.uk/id/eprint/1461121/