Back to search

UCL (University College London)

Microbubbles as a quantitative contrast agent for x-ray phase contrast imaging

Abstract

dc:description.abstract

Work presented in this thesis demonstrates how x-ray phase based imaging methods can be used to measure microbubble concentration. Experiments were first performed using a synchrotron analyser crystal based method to gain benchmark data, before testing with a laboratory based edge illumination method under development at University College London. A single-shot analyser based imaging method was also demonstrated at the synchrotron which gives the potential for time resolved imaging. If microbubbles are to be imaged in-vivo then they will likely be in flow within the circulatory system. To find how this impacts on detected signal a flow phantom was developed which can control fluid flow rate, and the flowing microbubble concentration. Synchrotron results are presented demonstrating how x-ray phase based imaging can be used to dynamically track changes in microbubble concentration. A Monte Carlo model was also developed to simulate the signal generated by microbubbles using both synchrotron and laboratory based methods. Three-dimensional numerical phantoms were created to directly model experimental samples, with signal generated by these then simulated using both methods. The Monte Carlo model of the laboratory edge illumination system was the first fully three-dimensional and polychromatic model developed. This was validated against experimental data acquired with a prototype edge illumination system, and so in future could be used to aid the development of further systems. It can provide information helpful in the design of masks, geometry, source and detector specifications, as well as giving an indication of the systems tolerance to misalignment. The use of microbubbles as a contrast agent for x-ray phase contrast imaging could both transform x-ray imaging into a “functional” modality and enable much needed real time monitoring of targeted drug delivery. Results presented in this thesis demonstrate this to be possible, and encourage further research in this area.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Millard, TP

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1470310/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Millard, TP. Microbubbles as a quantitative contrast agent for x-ray phase contrast imaging. Doctoral thesis, UCL (University College London), 2015. https://discovery.ucl.ac.uk/id/eprint/1470310/