Back to search

UCL (University College London)

Towards greater clarity for the analysis of imaging studies: Development & validation of an alternative to the area under the receiver-operator characteristic curve.

Abstract

dc:description.abstract

This thesis arose from a 2006 study performed by the author and his collaborators that attempted to gain regulatory approval for computer-assisted detection (CAD) software. The USA Food & Drug Administration (FDA) obliged us to use the change in the area under the receiver-operator characteristic curve (ROC AUC) as our primary outcome. Despite its wide dissemination in radiology research, we found implementation of ROC AUC very problematic. This thesis explores the hurdles we encountered and argues for an alternative approach. Chapter 1 describes the rationale for and against ROC AUC as a measure of diagnostic performance. An alternative analysis based on net benefit is proposed on the basis that it is more transparent and simpler to interpret. Chapter 2 uses the net benefit method to analyse a multi-reader multi-case (MRMC) study of CAD for CT colonography. The analysis requires an estimate of relative misclassification costs for false-negative versus false-positive diagnoses; “W”. This study used a conservative value for W, arrived at via consensus. In Chapter 3 an evidence-based value for W in the context of screening for colorectal cancer and polyps by CT colonography is arrived at via a discrete choice experiment (DCE) of patients and healthcare workers. Chapter 4 uses the value for W obtained in Chapter 3 in a net benefit analysis to compare observer performance in two MRMC studies of CAD for CT colonography. Chapter 5 obtains W by DCE for a different clinical context – detection of extracolonic pathology by CT colonography. Chapter 6 describes a systematic review that aims to determine whether reporting of MRMC ROC AUC methods in the radiological literature is comprehensive. Chapter 7 then provides guidelines for the comprehensive reporting of MRMC ROC AUC studies. The thesis finishes with a summary of the work performed and suggestions for further research.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Halligan, SM

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1472422/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Halligan, SM. Towards greater clarity for the analysis of imaging studies: Development & validation of an alternative to the area under the receiver-operator characteristic curve.. Doctoral thesis, UCL (University College London), 2015. https://discovery.ucl.ac.uk/id/eprint/1472422/