Back to search

UCL (University College London)

Bio-analytics - from current clinical practice to all-optical microfluidic technology

Abstract

dc:description.abstract

There are many instances in which one would measure biological systems along a temperature gradient. This is because thermodynamics dictate the dynamics of biological processes. Here, systems are engineered where thermodynamic changes in biological systems are enacted by the use of optical heating. This optical heating allows the use of microfluidic analysis systems in making measurement of these changes. Furthermore, measurement of the temperature changes themselves aremade remotely of the sample, utilizing optical techniques. Overall these methods results in measurement of changes in biological systems, in relation to temperature change, using much lower volumes of valuable samples and reagents, than in comparable commercially available systems. Specifically the stability of a fluorescent protein was measured in a bespoke microfluidic device using all optical heating, enacted by use of a infra-red laser. By measuring the decrease in fluorescence of that protein as it became thermally denatured. This was performed using a measured volume of 15nl which is many orders of magnitude less than that used in a commercially available system. Work is ongoing, to generalize this, to nonfluorescent proteins by measuring the change in intrinsic fluorescence of proteins, as a function of temperature. A key technology in which temperature changes are enacted in a biological system is PCR, here controlled cycling of temperature is performed to induce an exponential increase in the amount of a DNA target. This process underpins sequencing of DNA as it allows enough DNA for the sequence to be detected. A microfluidic device would be constructed to perform PCR thermocycling using optical heating and thermometry. Prior to this a DNA sequencing study was conducted of the mutational patterns of HBV in a clinical scenario. This study would provide sample for, and would be used as a comparison for the construction of a microfluidic all optical qPCR device.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Aoudjane, S

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1477634/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Aoudjane, S. Bio-analytics - from current clinical practice to all-optical microfluidic technology. Doctoral thesis, UCL (University College London), 2016. https://discovery.ucl.ac.uk/id/eprint/1477634/