Back to search

UCL (University College London)

Pre-1919 suspended timber ground floors in the UK: estimating in-situ U-values and heat loss reduction potential of interventions

Abstract

dc:description.abstract

Space heating demand in dwellings accounts for around 13% of the UK's CO2 emissions. In support of the UK's carbon emission reduction targets, the UK's existing housing stock would benefit from its thermal performance being characterised. This would facilitate decision-making in the reduction of space-heating energy demand through retrofit. Approximately 25% of the UK's 26 million dwellings pre-date 1919 and are predominantly of suspended timber ground floor construction, the performance of which has not been extensively investigated at present. While under-floor insulation uptake may increase under future government policies, the actual thermal performance of suspended timber ground floors and the implications of insulating them are poorly characterised at present. This PhD research used in-situ heat-flow measuring techniques and the research improved and added knowledge and understanding to the methodological approaches of in-situ estimation of floor U-values, the in-situ estimated U-value of a small number of suspended timber ground floors and the effect of some insulation interventions. Findings highlighted a significant variation in 'point' U-values across the floor with increased thermal transmittance observed along the exposed perimeter and near airbrick locations. This additionally highlighted that obtaining 'whole' floor U-values from a limited number of measured point locations on a floor with large heat-flow variations is challenging. Furthermore, insulation interventions significantly reduced floor U-values and generally a significant disparity was found between modelled and measured U-values. Current models appeared to underestimate the 'whole' floor measured U-value for the floors monitored and this disparity reduced the better insulated the floor. Using current floor U-value models might result in misguided retrofit strategies due to the observed disparity between in-situ estimated and modelled floor U-values as found in a small sample in this study. If these observations are more broadly confirmed in the pre-1919 housing stock, it could have significant implications for policy and retrofit decision-making.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pelsmakers, SLJ
Contributors dc:contributor
  • Elwell, C
  • Croxford, B
  • Shipworth, D

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1505859/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Pelsmakers, SLJ. Pre-1919 suspended timber ground floors in the UK: estimating in-situ U-values and heat loss reduction potential of interventions. Doctoral thesis, UCL (University College London), 2016. https://discovery.ucl.ac.uk/id/eprint/1505859/