Back to search

UCL (University College London)

Image synthesis for the attenuation correction and analysis of PET/MR data

Abstract

dc:description.abstract

While magnetic resonance imaging (MRI) provides high-resolution anatomical information, positron emission tomography (PET) provides functional information. Combined PET/MR scanners are expected to offer a new range of clinical applications but efforts are still necessary to mitigate some limitations of this promising technology. One of the factors limiting the use of PET/MR scanners, especially in the case of neurology studies, is the imperfect attenuation correction, leading to a strong bias of the PET activity. Exploiting the simultaneous acquisition of both modalities, I explored a new family of methods to synthesise X-ray computed tomography (CT) images from MR images. The synthetic images are generated through a multi-atlas information propagation scheme, locally matching the MRI-derived patient's morphology to a database of MR/CT image pairs, using a local image similarity measure. The proposed algorithm provides a significant improvement in PET reconstruction accuracy when compared with the current correction, allowing an unbiased analysis of the PET images. A similar image synthesis scheme was then used to better identify abnormalities in cerebral glucose metabolism measured by [18]F-fluorodeoxyglucose (FDG) PET. This framework consists of creating a subject-specific healthy PET model based on the propagation of morphologically-matched PET images, and comparing the subject's PET image to the model via a Z-score. By accounting for inter-subject morphological differences, the proposed method reduces the variance of the normal population used for comparison in the Z-score, thus increasing the sensitivity. To demonstrate that the applicability of the proposed CT synthesis method is not limited to PET/MR attenuation correction, I redesigned the synthesis process to derive tissue attenuation properties from MR images in the head & neck and pelvic regions to facilitate MR-based radiotherapy treatment planning.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Burgos, NF
Contributors dc:contributor
  • Ourselin, S
  • Hutton, BF
  • Cardoso, MJ

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1517860/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Burgos, NF. Image synthesis for the attenuation correction and analysis of PET/MR data. Doctoral thesis, UCL (University College London), 2016. https://discovery.ucl.ac.uk/id/eprint/1517860/