Back to search

UCL (University College London)

Source Modelling of the Human Hippocampus for MEG

Abstract

dc:description.abstract

Magnetoencephalography (MEG) is a neuroimaging technique which gives direct non-invasive measurements of neuronal activity with high temporal resolution. Given its increasing use in cognitive and clinical research, it is important to characterize, and ideally improve upon, its advantages and limitations. For example, it is conventionally assumed to be insensitive to deep structures because of their distance from the sensors. Consequently, knowledge about their signal contribution is limited. One deep structure of particular interest is the hippocampus which plays a key role in memory and learning, and in organising temporal flow of information across regions. A large body of rodent studies have demonstrated quantifiable oscillatory underpinnings of these functions, now waiting to be addressed in humans. Due to its high temporal resolution, MEG is ideally suited for doing so but faces technical challenges. Firstly, the source-to-sensor distance is large, making it difficult to obtain sufficiently high signal-to-noise ratio (SNR) data. Secondly, most generative models (which describe the relationship between sensors and signal) include only the cortical surface. Thirdly, errors in co-registering data to an anatomical image easily obstruct or blur hippocampal sources. This thesis tested the hypotheses that a) identification and optimisation of acquisition parameters which improve the SNR, b) inclusion of the hippocampus in the generative model, and c) minimisation of co-registration error, together enable reliable inferences about hippocampal activity from MEG data. We found the most important empirical factor in detecting hippocampal activity using the extended generative model to be co-registration error; that this can be minimised using flexible head-casts; and that combining anatomical modelling, head-casts, and a spatial memory task, allows hippocampal activity to be reliably observed. Hence the work confirmed the overall hypothesis to be valid. Additionally, simulation results revealed that for a new generation of MEG sensors, ~5-fold sensitivity improvements can be obtained but critically depend on low sensor location errors. These findings set down a new basis for time-resolved examination of hippocampal function.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Meyer, SS

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1534537/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Meyer, SS. Source Modelling of the Human Hippocampus for MEG. Doctoral thesis, UCL (University College London), 2016. https://discovery.ucl.ac.uk/id/eprint/1534537/