UCL (University College London)
Analysis of the embodied and operational energy: Study of a suburban house in Athens, Greece
Abstract
dc:description.abstractOperational energy can establish how successful a building is, in terms of environmentally 'considerate' design. Though embodied energy of construction materials also comprises an important indicator of the environmental impact of the material, the construction industry does not really promote it as such. This report enhances the significance of embodied energy and its relationship to operational energy (energy in use). Since buildings are becoming less energy demanding, operational energy will be decreasing, so that embodied energy will be gaining ground in the attempt to protect the environment. By the use of an 'environmentally friendly' house as a case study, it was proven that, though changes of the wall, floor, and insulation materials can take place, the operational energy does not change. What is greatly affected is the embodied energy of these construction materials.
Degree
thesis:*- Level dc:type.qualificationlevel
- Doctoral
- Grantor dc:publisher.institution
- UCL (University College London)
- Year dc:date.issued
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ghiata, M
Rights
- Language dc:language
- en, eng
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- https://discovery.ucl.ac.uk/id/eprint/1567781/