Back to search

UCL (University College London)

Evaluation of energy efficient design competition of a public office building in North Greece

Abstract

dc:description.abstract

Over the past few years in Greece there have been changes in the National Environmental and Energy Policy related to sustainability and energy conservation-saving, concerning the built environment as well. In this context, in 1999, the Hellenic Public Real Estate Corporation announced a Public Open Competition for the "Design and Construction" of a Police Station in the city of Kilkis, in North Greece. The energy efficiency and bioclimatic design was part of the General Design Principles of the brief. The following Report aims at evaluating the energy performance of the building and the comfort levels in the internal environment and determining the benefits of incorporating environmental design in a Public Office Building, in terms of savings in the energy consumption for heating. The Methodology included a description of the features of the design, analysis of the differences between the initial design and the constructed building, investigation of the operation of the constructed building (monitoring, questionnaire survey, energy consumption) and evaluation of the effect of the differences mentioned, using computer simulation (TAS software). Internal Temperatures fluctuated less than the external but for most of the monitoring period (end of mid-season-beginning of summer) Maximum Temperatures were higher than the external. The occupants gave positive comments and evaluated the general working conditions in the building as good, but the majority were not aware of the Passive Solar Systems installed in the building. The actual energy consumption for heating (150.85kWh/m2) is approximately 85% of the average consumption of Public Office Buildings in North Greece but 50% higher than that of recently built Public Office Buildings. However, the figure from the simulation analysis (corresponding to Office and Common spaces) is approximately 1/3 of the actual (55.14 kWh/m2), suggesting that proper operation of the building could result in significant reduction in energy required for heating.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chatzimanoli, A

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1568387/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Chatzimanoli, A. Evaluation of energy efficient design competition of a public office building in North Greece. Doctoral thesis, UCL (University College London), 2005. https://discovery.ucl.ac.uk/id/eprint/1568387/