Night ventilation strategies in Korean apartment units: Ventilated apartment and solar chimney

Abstract

dc:description.abstract

This paper is aimed at estimating the effect of various factors on the heating energy consumption and introducing night ventilation strategies to reduce cooling load in Korean apartment using TAS Modeller, TAS Ambiens and QuickSTREAM. The factor considered this paper type of remodelling, insulation level, window type and reset an internal temperature. The natural ventilation strategies considered here night ventilation, night flush cooling and solar chimney. Base on some assumption, an actual apartment unit is simplified into a model that is used for heating load in winter and looking into internal condition in summer night. The simplified model is validated by showing a good agreement with the actual one in heating load result. Refurbished balcony has a benefit in reducing heating load by 15%. Remodelled apartment is sharply increased in thermal load which must be avoided in view of energy conservation as well as structural problem. The most efficient and the easiest way of reducing heating load in current apartment are to set the internal temperature at 20 C. In second part of the simulation, we confirmed that it is possible to use natural ventilation for physiological cooling, night flush cooling to cooled structure and cooperating with solar chimney during the summer night time to reduce PAC's operating hours. The best case exceeds the bench mark temperature which is based on all windows being open all day. The CFD and Psychrometric chart results support to use of natural ventilation strategies in Korean apartments and shows that when Korean apartments adapt the night ventilation strategies, the occupants does not feel turning on the PAC system during cooling period time.

Degree

thesis:*
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
UCL (University College London)
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kim, YK

Rights

Language dc:language
en, eng

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://discovery.ucl.ac.uk/id/eprint/1569551/

Chain of custody

source
Harvested from
University College London
Base URL
discovery.ucl.ac.uk/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Kim, YK. Night ventilation strategies in Korean apartment units: Ventilated apartment and solar chimney. Doctoral thesis, UCL (University College London), 2015. https://discovery.ucl.ac.uk/id/eprint/1569551/