University of Connecticut
The Effect of Fuel and Air Side Contaminants in a Proton Exchange Membrane Fuel Cell and Methods for Mitigation
Abstract
dc:description.abstractInvestigations into the effects of fuel and air side contaminants within a proton exchange membrane fuel cell (PEMFC) were conducted via the introduction of selected contaminants in a controlled environment. Results show low electrical costs for hydrogen (>99% purity) production (<$2.00/kg), while utilizing the electrochemical separation of CO in a pulsed hydrogen pump system. Mitigation techniques within a PEMFC have shown a reduction in the voltage loss by a factor of 5 while operating with 1% CO at 400 mA/cm2. Lastly, cation contaminants were observed to accelerate the pitting corrosion on the aluminum sublayer of gold plated aluminum, within an acidic PEMFC simulated environment.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Discipline thesis:degree_discipline
- Mechanical Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Leamon, Eric G
- Contributors dc:contributor
-
- Dr. Michael Pettes, Dr. Prabhakar Singh
- Dr. Ugur Pasaogullari
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.lib.uconn.edu/gs_theses/873