University of Missouri--Kansas City
The Effect of Simulated Oral Conditions on Surface Roughness and Friction Properties of Surface-treated and Non-surface Treated Nickel-Titanium Archwires: A Pilot Study
Abstract
dc:description.abstractThis study examined the effect of simulated oral conditions (storage in phosphate-buffered saline (PBS) with bracket-related load deflection at 37±1°C for 12 weeks) on surface-treated and non-surface treated NiTi archwires. Three types of NiTi wires were tested: non-coated NiTi wire, nitrogen-treated NiTi wire, and rhodium-coated NiTi wire. Wire segments from each NiTi wire type underwent surface roughness measurements and friction testing in the as-received condition (control group) and following exposure to a simulated oral environment for 12 weeks (experimental treatment group). A profilometer was used to measure average roughness in three areas of each wire segment. After profilometry, a universal mechanical tester was used for friction testing. Each wire segment was pulled through a bracket in a passive configuration for 5 mm and the minimum, maximum, and mean of the top 10% of the load was calculated. Three representative specimens from each NiTi wire type in each condition were viewed using scanning electron microscopy (SEM) to provide qualitative surface topography analysis. Results of the study showed that all wires stored in simulated oral conditions (PBS at 37±1°C with bracket-related load deflection) were significantly rougher (p < 0.05) than their counterparts in the as-received condition. Rhodium-coated wires were found to be significantly rougher (p < 0.05) than nitrogen-treated and non-coated NiTi wires across conditions (as received or following exposure to simulated oral conditions). All wires stored in simulated oral conditions also showed significantly increased friction forces (p < 0.05) following exposure to simulated oral conditions when compared to as-received counterparts. There was not a significant correlation (p > 0.05) between changes in surface roughness and associated friction. All wires stored in simulated oral conditions exhibited a more irregular surface topography than their as-received counterparts. Non-coated and nitrogen-treated wires showed increased particulate exposure and pitting corrosion after storage in simulated oral conditions, but only at higher magnification (1000x and 4000x). Rhodium-coated wires had the most irregular surface in both the as-received condition and following exposure to simulated oral conditions. Rhodium-coated wires also exhibited significant coating breakdown and loss at all magnifications (200x, 1000x, and 4000x) after storage in simulated oral conditions.
Degree
thesis:*- Name thesis:degree_name
- M.S. (Master of Science)
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Oral and Craniofacial Sciences (UMKC)
- Grantor
- University of Missouri--Kansas City
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Becker, Mary
- Advisors dc:contributor.advisor
-
- Walker, Mary P.
- Nickel, Jeffrey C. (Jeffrey Charles), 1957-
Subjects
dc:subject × 3Rights
- Language dc:language.rfc3066
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10355/70624