University of Missouri--Kansas City
Use of Biomechanical Motion Analysis and Pelvic Surgery Simulator for the Prevention of Surgical Errors in Mid-urethral Sling Anti-Incontinence Surgery
Abstract
dc:description.abstractMore than 200 million surgeries are performed annually worldwide in which preventable complications occur in up to 22 percent of these surgeries, with permanent disability rates between 0.4 - 0.8 percent. Resident surgeons are more likely to commit surgical errors as they start their surgical career with less mastery and surgical skills. Yet other than close supervision in the operating room, there is no accepted way to teach a young surgeon how to prevent surgical errors. This work discusses a method that was focused on identifying and modeling individual surgical errors to improve the training of individual surgeons and complement systems approaches, and thus lead to effective error prevention. This technique involved a combination of virtual and physical anatomic models, simulation of surgical injury, and kinematics of both surgeon and surgical instrument to identify, model and describe surgical errors quantitatively. This study targets a complex, high-risk step of the Midurethral Sling surgery which is highly effective in reducing stress urinary incontinence. This surgery involves the insertion of a strip of mesh underneath the urethra and the surgeon is tasked with blindly guiding a sharp steel trocar behind the pubic symphysis and past the bladder, bowel, and major blood vessels. If the trocar is not guided properly through its passage (from vagina to the suprapubic skin), it can lead to several injuries, such as injury to the bladder or urethra (4.9%), injury to the bowel (0.1%), and injury to external iliac vessels (2.0%). This work effectively integrates the concepts and theories from both biomechanical engineering and medicine (surgery), including MRI segmentation, development of subject-specific virtual and physical models, motion capture technology, testing cadaveric specimens, multi-body modeling, musculoskeletal modeling, and simulation. Three MUS physical pelvic floor models were developed by segmenting the pelvic bones and organs from MR images of three patients with stress urinary incontinence. Segmented pelvic bone structure was 3D printed and the open space between the bone was filled with thermoballistic gel to provide the haptic feedback associated with soft tissue during the retropubic trocar passage. Vital injuries during the Midurethral sling Surgery (MUS) can be avoided by maintaining constant contact between the trocar tip and pubic bone, yet this is challenging for a teaching surgeon to monitor during this blind procedure. A force-sensing trocar was developed by modifying the retropubic trocar with a load cell which can distinguish on-bone and off-bone movement during the procedure. Two expert and three novice surgeons performed retropubic trocar passage on the MUS physical pelvic floor model using the modified trocar. Bio-fidelity of the MUS physical model was assessed by analyzing the force variables in the expert passages performed on a thiel-embalmed cadaver and the MUS physical model, using this force-sensing trocar. Test-retest analysis was conducted to analyze the force-sensitivity of this proposed model-trocar system using trocar passages performed on the MUS physical model two weeks apart. Post-hoc analyses were performed to compare the expert vs. novice performance on the physical model. Three expert and three novice surgeons participated in the kinematic study where both the surgical instrument (trocar) and surgeon body movements were tracked. Both the surgical instrument and surgeon body were equipped with retroreflective markers to facilitate the motion tracking during this procedure, using OptiTrack Flex 13 motion capture system. Multibody kinematic models were developed in MSC ADAMS to analyze the surgical instrument kinematics. Musculoskeletal models were developed using OpenSim to analyze the surgeon body kinematics during the retropubic trocar passage. Simulated trocar passage (from the vaginal incision point to the exit point at rectus fascia) was separated into 4 stages for the purpose of analysis. Mixed model analysis was used to analyze the trocar trajectories, temporal data, and surgeon upper extremity kinematic variables obtained from the retropubic passages performed by each participant. Paired sample t-tests revealed no statistically significant differences on the outcome force variables between trocar passages performed on cadaver and MUS physical model, suggesting adequate bio-fidelity of this physical pelvic model. Test-retest analysis also exhibited no significant difference between the testing sessions on any of the outcome variables. Independent sample t-tests revealed significantly larger amplitude of maximum force development, larger maximum rate of force development and shorter time to reach the maximum force in the expert participants than the novices. Simulated trocar passages in the multibody models revealed that the experts completed 27 error-free passages and 18 bladder error passages (40%). Novices completed 18 error-free passages, 4 bladder error passages and 23 anterior error passages, resulting in an overall error rate of 60%. Mixed model analysis revealed that the trocar tip trajectories were significantly different between the error free passages and the bladder error passages in the anterior-posterior and caudal-cephalad directions for both left and right shoulder passages. The incidence of the anterior error passages was significantly higher in the novices for both left and right directions. Experts had significantly longer mean trial duration and path length, compared to the novices. Mixed model analysis was also used to analyze the total trocar path variation which indicated that 48% of variation was attributed to the novices, where only 14% path variation was attributed to the experts. Mixed model analysis of the surgeon body kinematic variables revealed that the bladder contact trials were significantly associated with higher starting wrist dorsiflexion, less final elbow flexion and greater range of motion in both wrist dorsiflexion and elbow flexion at stage 3. Anterior versus posterior passage analysis performed on stage 1 indicated this incidence is significantly associated with less elbow flexion. Expert versus novice analysis revealed that novices had significantly higher range of motion in elbow flexion, but less range of motion in wrist dorsiflexion and arm pronation during stage 1, compared to the experts. However, stage 2 exhibited less range of motion with arm pronation and less range of motion with shoulder flexion in the novices. This study suggests high test-retest reliability and adequate bio-fidelity of the modified trocar used on our MUS 3D surgery simulator. This innovative trocar can be used both in surgical simulation and in the operating room to help the novice stay on the bone, and to help the attending monitor safe surgery. Kinematic analysis of the surgical instrument movement indicated that the novice passages were predominantly anterior to the pubic bone. In addition, significantly higher trocar path variation in the novices suggests that they were not able to follow a consistent trocar path between trials. Surgeon upper extremity kinematics indicate that expert participants exhibited more consistency with the distal joints (wrist and forearm), while the novices mostly focused on the proximal joints (elbow). Monitoring the temporal and kinematic characteristics of trocar, and the surgeon body kinematics provides useful insights into the types of errors occurred during retropubic trocar passage and has the potential to provide insight into proper education of surgical trainees. This is the first study that incorporated motion capture technology with a high-fidelity 3D pelvic surgery simulator to track the surgical instrument and surgeon body movements during the MUS procedure. Methods used in this study has the potential to be used for monitoring the sling placement in the operating room, accelerate the learning experience of novice through insights from surgeon kinematics, thus lead to effective error prevention in the midurethral sling surgery.
Degree
thesis:*- Name thesis:degree_name
- Ph.D. (Doctor of Philosophy)
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Engineering (UMKC)
- Grantor
- University of Missouri--Kansas City
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Arif, Md Arifuzzaman
- Advisors dc:contributor.advisor
-
- Stylianou, Antonis P.
- Bani-Yaghoub, Majid
Subjects
dc:subject × 4Rights
- Language dc:language.rfc3066
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10355/96474