Back to search

University of Minnesota

Design, implementation, and calibration of physics Half-Wave Plate polarimetry for the E and B Experiment

Abstract

dc:description.abstract

The E and B Experiment (EBEX) is a balloon-borne telescope designed to measure the polarization of the Cosmic Microwave Background (CMB) and dust foregrounds at 10' scales and three frequency bands of 150 GHz, 250 GHz, and 410 GHz in order to detect or constrain B-mode polarization. Results may provide evidence to support the theory of cosmological inflation, or constrain specific models.EBEX's polarization measurement capability is implemented via continuously-rotating Half-Wave Plate (HWP) polarimetry. We discuss the design and implementation of the polarimetry hardware for the E and B Experiment (EBEX). In order to achieve low-temperature rotation of our 15 cm, 635 g achromatic HWP stack, we implement a unique application of a Superconducting Magnetic Bearing (SMB), building off an earlier prototype. We discuss design constraints, detail our implementation, and present results of tests of power dissipation, rotation speed stability, dynamic stability, and operational lifetime. We find power dissipation of 15 mW in our LDB configuration, and achieve successful operation of the system in both a 2009 test flight and a 2012 Long Duration (LDB) flight.We design and carry out calibration tests to verify our ability to measure polarized signals. We develop a data analysis pipeline to extract polarization measurements from the chopped polarized signals we use in calibration; we verify and optimize the performance of this pipeline with a simulation. We find that a thorough understanding of the time constants of EBEX's bolometric sensors is essential to measure polarization. We develop methods to measure and remove the effects of these time constants. Tests of polarization rotation across our bands verify predictions of rotation due to our achromatic HWP 5-stack. Polarized beam scans allow us to set an absolute calibration for EBEX with a standard deviation of 1.5 degrees.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Klein, Jeffrey Michael

Subjects

dc:subject × 7

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Klein, Jeffrey Michael. (2014). Design, implementation, and calibration of physics Half-Wave Plate polarimetry for the E and B Experiment. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/168255.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Klein, Jeffrey Michael. Design, implementation, and calibration of physics Half-Wave Plate polarimetry for the E and B Experiment. 2014. http://hdl.handle.net/11299/168255