Back to search

University of Minnesota

Ultra-low Frequency Electron Paramagnetic Resonance Based on Longitudinal Detection and Fictitious Field Modulation

Abstract

dc:description.abstract

In magnetic resonance imaging, the signal intensity is directly affected by the external field strength and the spin system properties. It is challenging to acquire signal from electron spins at ultra-low field because of their short relaxation times: the weak signal would decay away before it can be captured. The longitudinal detec- tion (LOD) of electron paramagnetic resonance (EPR) offers an alternative solution. Instead of measuring the transverse magnetization, LOD measures the longitudinal magnetization along the polarizing field direction. By placing the receive coil or- thogonal to the transmit coil and tuning it to a different frequency range, an LOD EPR system can have superior resilience against transmit cross-talk and enables si- multaneous transmit and receive. As a result, the EPR signal from spins with short relaxation times can be recorded with high signal to noise ratio. This thesis presents an ultra-low field LOD EPR measurement system. A novel method of inducing signal from longitudinal magnetization is described: fictitious field modulation. When viewed in a rotating frame of reference, a transverse-plane radiofrequency (RF) field manifests as a longitudinal field component called the fic- titious field. By modulating the RF field and thus the fictitious field, detectable longitudinal magnetization patterns are measurable. Furthermore, via combining fictitious-field modulation and longitudinal detection, this work demonstrates EPR spectroscopy and one-dimensional imaging. This custom-built LOD system oper- ates at an ultra-low frequency (24 MHz) for detecting electron spins with short (∼nanoseconds) relaxation times. Simultaneous transmit and receive with low trans- mitter leakage level (∼80 dB isolation) is also achieved. Finally, a different version of this system is introduced for measuring short relaxation times at ultra-low magnetic field, the principle of which is derived from the fictitious field theory.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • TANG, XUEYAN

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
TANG, XUEYAN. (2021). Ultra-low Frequency Electron Paramagnetic Resonance Based on Longitudinal Detection and Fictitious Field Modulation. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/224556.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

TANG, XUEYAN. Ultra-low Frequency Electron Paramagnetic Resonance Based on Longitudinal Detection and Fictitious Field Modulation. 2021. https://hdl.handle.net/11299/224556