Back to search

University of Minnesota

Development of self-supporting helical ribbon linear actuator for IMRI surgeries.

Abstract

dc:description.abstract

Intraoperative Magnetic Resonance Imaging (iMRI) surgeries are high-risk procedures performed within an MRI suite, commonly for conditions such as brain tumors and epilepsy. During these operations, clinicians often need to adjust the patient’s position to improve access to the surgical site. Currently, this repositioning is done manually with the aid of cushions, which can introduce significant risks to patient safety and increase the likelihood of complications. Moreover, manual adjustments extend the overall procedure duration, increasing the surgeon's time in the operating room and potentially affecting surgical outcomes. Addressing these challenges is critical to enhancing both patient safety and surgical efficiency.To address this issue, clinicians and surgeons were consulted during the Voice of Customer (VOC) stage, leading to the identification of key requirements based on their feedback. These insights were translated into a clear need statement, guiding the ideation process. After exploring various concepts through brainstorming sessions, a solution involving an array of linear actuators embedded within the MRI bed was selected. These actuators can be externally programmed to adjust to common patient positions required during iMRI procedures, reducing manual intervention, enhancing patient safety, and improving surgical efficiency. A novel single-band helical ribbon linear actuator was developed for this application. The actuator features tabs and slots that engage upon deployment into a helical structure, forming a stable cylindrical column. The actuator’s dimensions were optimized through a Design of Experiments (DOE) to assess critical factors influencing the column’s overall stress. Finite Element Analysis (FEA) simulations in Ansys were conducted to identify the dimensions yielding the highest stress tolerance, guiding the final design specifications. A custom drive system was engineered to house and deploy the ribbon. Compressive testing on a prototype confirmed a yielding stress of 700 lbs, surpassing the failure threshold, validating the design’s robustness. The actuator achieves an 8:1 extension ratio within a compact 3” x 3” footprint, ideal for localized actuation on MRI beds. Constructed from non-magnetic materials, the actuator is compatible with MRI environments, offering a market-leading extension ratio while maintaining a minimal spatial footprint.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Soni, Yash

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Soni, Yash. (2025). Development of self-supporting helical ribbon linear actuator for IMRI surgeries.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/275815.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Soni, Yash. Development of self-supporting helical ribbon linear actuator for IMRI surgeries.. 2025. https://hdl.handle.net/11299/275815