Back to search

University of Minnesota

Effects of storage time on resin composite attachment characteristics in aligner template trays

Abstract

dc:description.abstract

Abstract Aim: The aim of this study was to evaluate the effect of pre-polymerization storage time on the mechanical and chemical properties of resin composite attachments fabricated using clear aligner template trays. Specifically, the study assessed how storage time influenced the microhardness, ambient light-induced polymerization, and shear bond strength of attachments bonded to enamel under simulated clinical conditions. Methods: Resin composite attachments were prepared using Tetric EvoCeram nanohybrid composite filled into clear aligner template trays and stored in opaque black retainer cases at 20°C for five time intervals: 1 hour, 1 day, 1 week, 2 weeks, and 1 month. Microhardness of cured samples was measured using a Vickers microhardness indenter. Ambient light-induced polymerization of uncured attachments was evaluated using FT-IR spectroscopy. Shear bond strength of attachments bonded to human premolars was tested using a universal testing machine. A total of 26 samples per time point were tested for microhardness, 28-29 samples for spectroscopy, and 6-8 premolars per time point for shear bond strength. Statistical analysis included ANOVA with post hoc Tukey testing, with significance set at p<0.05. Results: Microhardness values showed significant differences across time points (ANOVA p=0.0004), with the greatest hardness at 1 week and significantly lower values at 1 day (p=0.0002) and 2 weeks (p=0.0107). FT-IR absorbance at 1640 cm-1 also differed significantly between certain groups (ANOVA p < 0.0001), with the lowest absorbance at 1 day and unexpectedly high absorbance at 1 week, suggesting inconsistent ambient light exposure rather than a linear polymerization trend. Shear bond strength did not differ significantly between time points (ANOVA p=0.032), with all groups exceeding clinically acceptable bond strength thresholds. Conclusions: No clear relationship was found between the pre-polymerization storage time of attachments up to one month and the microhardness, degree of dark curing, and shear bond strength of aligner attachments. Handling time and ambient light exposure may have a greater effect on the mechanical and chemical properties of attachments compared to storage time. Future studies should investigate additional composite materials and environmental controls to refine guidelines for pre-filled aligner storage.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Obeng, Kaimen

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Obeng, Kaimen. (2025). Effects of storage time on resin composite attachment characteristics in aligner template trays. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/276718.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Obeng, Kaimen. Effects of storage time on resin composite attachment characteristics in aligner template trays. 2025. https://hdl.handle.net/11299/276718