Back to search

University of Minnesota

Particle size characterization of virus-laden aerosols and evaluation of an electrostatic precipitator to reduce viral airborne transmission

Abstract

dc:description.abstract

Airborne diseases pose a threat to both humans and animals. The rapid spread of airborne pathogens makes them difficult to contain and protect against. Proper characterization of viral aerosols is crucial to understand the airborne transmission of viruses and help establish effective control measures. Evaluation of new air cleaning technologies is also needed to help prevent or reduce the spread of airborne diseases. The overall objective of this thesis was to improve the characterization of virus-laden aerosol particles regarding size distribution, viral load and virus viability, and to evaluate an air cleaning technology to remove viral aerosols and reduce viral airborne transmission in pigs under experimentally conditions.The Andersen cascade impactor (ACI) is an air sampler that collects and separates airborne particles into different size intervals. However, particles may bounce upon impact with the collection plates of the ACI and deposit onto the lower stages, leading to the measurement of particles as being smaller than their true size. In our study, we investigated the effect of different coating materials applied on collection plates of the ACI to prevent particle bounce while conserving virus viability during the collection of viral aerosols. Viral aerosols were artificially generated in a single-pass wind tunnel. The size distribution, viral load and viability of viral aerosols measured by ACIs with either coated or uncoated plates were similar. The size distribution of the virus-laden particles measured was not shifted toward smaller sizes. Our results indicated that there was no need to use coating materials to prevent particle bounce under the conditions of this study. However, we did identify potential coating materials which could conserve virus viability maximally, if particle bounce is of concern. In order to provide alternatives to control the spread of airborne viruses, we evaluated an air cleaning technology, the electrostatic precipitator (ESP), to remove and inactivate experimentally generated viral aerosols of bovine coronavirus (BCoV), porcine reproductive and respiratory syndrome virus (PRRSV) and influenza A virus (IAV). Viral aerosols were generated in a wind tunnel and in isolator chambers, and air samples were collected simultaneously using ACIs upstream and downstream of the ESP. The ESP efficiently removed viral aerosols across multiple particle size ranges, especially for the larger particles. Furthermore, a portion of viruses appeared to be inactivated by the ESP. The ESP was further evaluated to mitigate airborne transmission of IAV and PRRSV in a setting with aerosols naturally generated by infected pigs. Experimentally inoculated pigs and sentinel pigs were housed in BSL-2 air-tight self-contained isolator chambers upstream and downstream of the ESP, respectively. Nasal swabs and air samples were collected daily. We found the ESP was able to remove significant amounts of virus-laden particles from the air, resulting in a delayed onset of IAV and PRRSV infections in sentinel pigs. These results showed the potential of the ESP to reduce the spread of airborne viruses in swine. We also characterized the viral load and size distribution of virus-laden particles emitted from IAV inoculated pigs over the course of infection, and explored factors contributing to airborne infection of sentinel pigs. The early viral emissions from infected pigs and the fairly low estimated infectious dose required to infect sentinel pigs through the air supported that aerosol transmission of IAV happens easily in pigs, which poses a risk. The studies in this thesis contributed new knowledge on methods to sample viral aerosols, and helped identify a promising air cleaning technology to reduce the spread of airborne viruses in swine. The findings on size distribution, viral load and viability of virus-laden particles generated from infected pigs help us better understand the transmission of airborne viruses, and provide useful information to help develop more effective infection control measures for airborne diseases in animals and humans.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wang, Lan

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Wang, Lan. (2024). Particle size characterization of virus-laden aerosols and evaluation of an electrostatic precipitator to reduce viral airborne transmission. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/278109.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Wang, Lan. Particle size characterization of virus-laden aerosols and evaluation of an electrostatic precipitator to reduce viral airborne transmission. 2024. https://hdl.handle.net/11299/278109