Abstract
dc:description.abstractThis dissertation focuses on three main research topics. One is the elimination of the loss of sensing components (i.e., plasticizer, ionic sites, and ionophore) in long term measurement (Chapter 2). The second is the elimination of the delamination of sensing membranes from the underlying platform substrate (Chapter 3-4). The third is the extension of the measurement range of pH sensors using two new covalently attachable ionophores with different H+ affinities (Chapter 5).Ion-selective electrodes (ISEs) are versatile chemical sensors that are widely used to measure pH in clinical settings, industrial process control, and environmental monitoring. Conventional ISEs with sensing membranes made of glass and inner filling solutions (Figure 1A) have several drawbacks that need to be overcome to meet the demands for miniaturized and wearable sensors with extended lifetimes and reduced frequency of recalibration. Efforts to overcome these drawbacks often involve ionophore-doped sensing membranes with solid contacts to the underlying electron conductor (Figure 1B). By forming complexes with the target ions, the ionophore in these sensing membranes enables the selective transfer to the target ions into the sensing membrane, resulting in charge separation at the interface of the sample and the sensing membrane and, thereby, the measured EMF response. Sensing membranes that comprise electrically neutral ionophores also must be doped with chemically inert ionic sites such as quaternary ammonium ions, which serve as counter ions to the target ions and lower the electrical resistance of the sensing membranes (Figure 1C). Compared to conventional ISEs, they have the distinct advantages of a lower impedance than glass-based sensors, a much reduced fragility, and increased robustness due to the absence of an inner filling solution. Moreover, using different ionophores, these sensors can be adapted for the detection of a variety of species other than H+ for a wide range of applications. Figure 1. Schematic representations of relevant electrode configurations. (A) Conventional ISE with a glass membrane and inner filling solution. (B) Solid-contact ISE with an ionophore-doped sensing membrane. (C) Equilibrium ion distribution between an aqueous phase and a membrane phase doped with neural ionophores (○) and anionic sites (R-): The phase boundary potential at the interface of the aqueous and organic phase is the origin of the familiar Nernstian response of ISEs. The lifetime of these ion-selective electrodes is primarily limited by leaching of plasticizer, ion receptor (ionophore), and ionic sites (to provide permselectivity) from the polymeric ion-selective membrane into the sample solution, and by delamination of the sensing membrane from the underlying substrate. My research addressed the former problem by covalently attaching either the ionophore or the ionic sites to a plasticizer-free polymer and testing the fundamental limitations of this approach. To prevent delamination of sensing membranes, I also developed photografting and plasma-induced polymerization methods that simultaneously attach the sensing membrane covalently to both inert polymeric electrode body materials and carbon conductors.My first research project focused on the chemical limitations of ISEs. The lifetime and potentiometric responses of ISEs are limited by leaching of sensing membrane components (plasticizer, ionophore, and ionic sites) from the polymer sensing membrane into sample solution. I addressed this problem by developing sensing membranes without plasticizer and with covalently attached ionophore and ionic sites. ISEs were prepared by using plasticizer-free poly(methacrylate) membranes in which only the ionic sites, only the ionophore, or both the ionic sites and ionophore were covalently attached to the poly(methacrylate) matrix (Figure 2). Because ionic sites have not been previously attached covalently to poly(methacrylate) membranes, I developed a methacrylate-based alkyl sulfonate ionic site for this purpose, and I determined the sensitivity, selectivity, response time, lifetime, and electrical resistance of the resulting sensors. My research debunked the long-held myth that covalent attachment of both the ionophore and the ionic sites is a general approach to increase electrode lifetime. Instead, I showed that only one of the two can be covalently attached to the polymer backbone, or else the sensor performance deteriorates drastically resulting in very slow response times. Prior work in this field had not properly taken into account impurities of ionophore and ionic site monomers that were not effectively attached to the sensing membrane in the polymerization process. This finding is of fundamental importance and will impact the work of researchers and industrial manufacturers who try to improve the lifetime of ISEs for any type of target ion by covalent attachment of ionophores and ionic sites to the sensing membrane. Figure 2. Three strategies to improve chemical stability of ISEs. Left: ISEs with covalent attachment of the ionic sites only. Center: Covalent attachment of both the ionophore and ionic sites. Right: Covalent attachment of ionophore only. To achieve long ISE lifetimes, my work is also addressing the physical limitations of ISEs. Upon extended exposure to aqueous solutions, upon thermal expansion, or in presence of mechanical stress, the sensing membrane of ISEs often delaminate from the underlying electrode body. This physically limits sensor lifetimes and is a major limitation to long-term monitoring with ISEs. To address this problem, I developed photografting and plasma-induced polymerization methods that simultaneously attach the sensing membrane covalently to both inert polymeric electrode body materials and carbon conductors (Figure 3). Figure 3. Schematic of direct seal of the ion-selective membrane (ISM) to both the underlying inert polymer and ion-to-electron transducer (solid-contact). While the covalent attachment of sensing membranes to polymeric substrates has been pioneered in the Buhlmann group by former graduate student Evan Anderson, my research is further improving this method by directly attaching the sensing membrane with covalent bonds to both the underlying polymer substrate and the ion-to-electron transducer consisting of nanoporous carbon. The latter not only improves the lifetime but also reduces signal drift and will help to minimize the need for recalibration. As the simultaneous attachment of ISE membranes to electrode bodies and the underlying conductor has never been performed before. To extend the measurement range of pH sensors, I also developed electrodes containing new covalently attachable ionophores with different H+ affinities (Figure 4). The range of the H+ response is limited by anion interference at low pH and cation interference at high pH. I developed the new pyridine-based hydrogen ionophore, 3-(pyridine-3-yl) propyl methacrylate, for extension of the upper detection limit and the new tertiary amine-based hydrogen ionophore, 10-(diisopropylamino)decyl methacrylate, for extension of the lower detection limit. The new less or more basic H+ ionophores provided a wide sensing range and a high selectivity, benefitting from the control of the H+ affinity, covalent attachment to the polymeric matrix, and direct sealing to underlying substrates. Figure 4. Two new ionophores to improve the measurement ranges of poly(decyl methacrylate) based H+-ISEs. Blue: the methacrylate-based pyridine methacrylate-based pyridine, 3-(pyridin-3-yl) propyl methacrylate, for the low pH range. Red: the tertiary amine ionophore, 10-(diisopropylamino)decyl methacrylate, for the high pH range.
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Choi, Kwangrok
Subjects
dc:subject × 6Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Citation
- Choi, Kwangrok. (2023). Chemical and physical limitations of electrochemical sensors. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/278774.