Resilient and situationally aware multi-microgrid: a stochastic control and resource pooling framework

Abstract

dc:description.abstract

In recent times, the proliferation of distributed energy resources, propelled by a mounting interest in the generation and utilization of clean renewable energy, has fostered a paradigm change in the operation and control of power distribution networks. Further, the impetus to create carbon-free power systems has incentivized the rapid growth of interconnected multi-microgrid frameworks that are powered by renewable energy sources (RESs). However, the inherent uncertainty of RESs poses a challenge in meeting the power demand of the microgrids (MGs) unless sufficient energy storage, such as battery energy resources (BESs), is maintained. While the energy storage systems can supply the deficit in the case of underproduction, an excess provisioning of energy storage systems can result in overproduction which in turn increases the operating cost. Since both overproduction and underproduction are undesirable, an important question that needs to be answered is: how can the MGs guarantee the demand-supply balance? In traditional distribution systems, MGs depend on the main grid for demand-supply balance and assistance with ancillary services. However, excessive grid dependency adversely affects system reliability as grid outages are becoming more frequent due to climate-related contingencies. Hence, designing an ecosystem of self-sufficient MGs that are capable of supplying local loads with local generations, while being minimally dependent on a centralized grid, is of considerable importance. In this context, it is crucial to devise a strategy for controlling the power output capability of the BESs to counter the uncertainty of RESs production and ensure that there will be no under and over-production simultaneously to improve the system reliability. Another crucial design aspect of the BESs is to ensure that they have sufficient energy capacity to minimize generation and load curtailments, arising due to over and underproduction scenarios. The BESs energy capacity should be designed in such a way that: (i) if the RESs produce more power than what is demanded by the load, then the BESs can be charged with the surplus generation, and (ii) when the RESs production is less than the required load, the BESs have sufficient energy to supply the deficit power. The above conditions are satisfied if the maximum capacity of BESs is not reached and the BESs never get depleted under the uncertainty presented by the RESs. Such a challenge in deciding the BESs capacity is further exacerbated by the uncertainty of RESs. While BESs with excess capacity can address the technical challenges of minimizing the generation and load curtailments, it increases the installation and operation cost of the entire system thus restricting the economical viability of maintaining BESs with huge capacities. Hence, in the planning stage of the system, it is essential to decide the minimum required BESs capacity to mitigate the RESs uncertainty with provable guarantee. For multi-microgrid systems, the facility to share power has the potential to harness the benefits of spatial diversity of generation to further minimize needed BESs capacity. In this context, it is essential to explore strategies to interconnect the MGs and to decide how the MGs should share power. While it is possible to reduce the required BESs capacity by interconnecting the MGs, the economic benefits of such a reduction may be nullified by the cost associated with the transmission lines connecting them. As the transmission line installation and maintenance cost primarily depends on the line flow capacity, it is essential to analyze the required capacity of both BESs and transmission lines in unison. In this thesis, Chapter 2 contributes towards developing a dynamic battery allocation and control strategy, under a novel electricity market mechanism, to optimize the power the battery reserve provides, while ensuring that demand is met with a provable guarantee. A power distribution system with multiple microgrids with stochastic RESs, and a distribution network operator (DNO) is considered. The objective of the DNO is to control the battery power output capability in such a way that the demands of all the microgrids, at the requested future time, are met with probability one without any over or underproduction. Our solution is built upon stochastic feedback control techniques. Under our proposed scheme, the DNO responds to the evolving uncertainty by dynamically balancing the RESs and battery resources, via contracts made in the electricity market, and eliminates the risk of over or underproduction. Chapter 3 contributes towards designing a methodology to determine battery capacity, for MGs, which ensures that during the operational phase, BESs’ operating range is respected with pre-specified high probability, under renewable uncertainties. We provide an explicit analytical expression of the required BESs energy capacity for a single microgrid with stochastic RESs as the main power source. Leveraging insights from the single microgrid case, the article focuses on the design and planning of BESs for an interconnected two-microgrid scenario. Utilizing stochastic feedback control theory, we propose an optimization framework to determine how the microgrids should share power, while respecting the transmission line capacity, to minimize the battery capacity requirement. Furthermore, we provide a theoretical analysis of the trade-offs between transmission line capacity and BESs energy capacity and show that for a large operation time horizon, it is even possible to reduce the transmission line capacity while maintaining the least amount of battery. Another important aspect of distribution system planning and control is to design a system monitoring infrastructure providing real-time situational awareness. To efficiently operate the system, the operator needs real-time measurements of bus voltages, power injection and flow through the branches, etc. Apart from the real-time measurements, another crucial information is the knowledge of the underlying power network topology. The network topology is utilized for various techno-economical purposes, such as economic dispatch, electricity price determination, etc. Traditionally the topology information is obtained from the prior knowledge of the system. However, the operational flexibility of renewable-powered MGs can alter the topology over time. Further, weather-related extreme events can result in branch faults in the system which changes the topology. Therefore, a methodology to detect and localize power network topology changes in real-time is extremely important to efficiently operate the system. To aid with such requirement, Information and Communication Technology (ICT) infrastructure is utilized. ICT infrastructure includes various modern measurement devices such as smart meters, phasor measurement units, etc. However, the wireless nature of such devices renders the system vulnerable to cyber-attacks. Many incidents of cyber-attacks in the energy sector have been reported in the last decade resulting in severe economic loss and electricity outages. The most common type of cyber-attack in this context is false data injection (FDI) attacks, where the attacker manipulates the field measurements to disrupt the system operation. The attack objectives range from technical interruptions, such as power outages, system faults, etc., to intrusion in economic operations, such as electricity markets. To this end, it is of utmost importance to devise cyber-attack detection and protection mechanisms to improve the resiliency of the system. In this thesis, Chapter 4 contributes towards developing a machine-learning method to detect and localize changes in a power network topology. The proposed strategy utilizes only bus voltages and phase angles to detect any change and further localize the change. The proposed strategy is capable of detecting multiple topology changes (branch outages or restoration) occurring simultaneously or over a time horizon. Real-time hardware-in-the-loop experiments on a modified IEEE 33-bus, 226-bus, and 1262- bus network, emulated on OPAL-RT real-time simulator, are conducted to demonstrate the efficacy of the proposed methodology. Chapter 5 of the thesis investigates system resiliency to cyber-attacks. In the first part of the chapter, cyber-attacks in breaker status measurements are considered. Such type of attack is capable of falsifying the topology information conveyed to the operator. Since the topology information is extensively used in deciding the electricity prices at different buses in the network, we demonstrate the impact of cyber-topology attacks in disrupting the electricity market. Utilizing reinforcement learning, we provide a system vulnerability analysis, by identifying the critical branches in the network, which must be protected to avoid such disruption. In the second part of the chapter we demonstrate the impact of FDI attacks in tertiary control of microgrids on system stability. We consider FDI attacks on measurements and control commands in a state-feedback-based controller and devise an attack detection and mitigation strategy. We conduct real-time controller hardware-in-the-loop validation on a microgrid emulated inside OPAL-RT to illustrate the utility of our proposed attack mitigation strategy. In Chapter 6 we describe an end-to-end cyber-physical testbed infrastructure for grid control and monitoring. The testbed is completely developed in the lab. The infrastructure is equipped with databases and a data-driven algorithm execution framework for experimental analysis of cyber-physical systems. Further, the testbed has real-life or emulated power system integration and visualization framework to assist with situational awareness. Some detailed real-time demonstrations on the testbed are illustrated to showcase the flexibility and utility of the same.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dey, Arnab

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Dey, Arnab. (2024). Resilient and situationally aware multi-microgrid: a stochastic control and resource pooling framework. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/278812.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Dey, Arnab. Resilient and situationally aware multi-microgrid: a stochastic control and resource pooling framework. 2024. https://hdl.handle.net/11299/278812