Back to search

University of Minnesota

Design And Guidance Testing Of A 3+Dof Robotic Adaptable Catheter System For Minimally Invasive Surgery

Abstract

dc:description.abstract

Current implementations of surgical robotics into minimally invasive surgery (MIS) have provided enhancements to cardiac interventions, promising lower patient mortality rates and greater ease of use by operators. Taking inspiration from these current systems, this thesis presents CathAdapt, a 3+ DOF robotically operated adaptable catheter system that converts steerable introducer sheaths (FlexCath ContourTM from Medtronic and AgilisTM NXT introducer from Abbott) and TAVR delivery catheters (EvolutTM FX from Medtronic) into a computer-controlled manipulator, capable of performing various intracardiac procedures by rapid interchange of medical devices when needed. CathAdapt uses two stepper motors for knob and handle rotation, respectively, and a third stepper motor for platform displacement with a linear guide rail, and is operated through a GUI program which monitors the pose of the catheter and imaging, depending on the device, in real-time. Ex-vivo motion validation tests demonstrated sub-millimeter positional error in linear translation-focused trials for the steerable introducers, with minor lower measurements recorded with the FlexCath ContourTM, though exhibiting a nearly linear behavior in its tip deflection with respect to the rotation angle given to the knob; the AgilisTM NXT introducer experienced greater inconsistencies in its steering behavior, mainly attributed to prior extended usage in the lab. In a pre-clinical, in-vitro setting, CathAdapt enabled rapid acquisition and fixed positioning of a simultaneous mitral and aortic valve view with the ICE catheter after two small corrective motions. Meanwhile, with the 2.4 mm videoscope, the robotic system provided constant visualization to regions of interest in the right atrium, though traversal to the pulmonary value resulted in occasional buckling on the shaft outside of the porcine heart. Overall, CathAdapt was able to provide precise, repeatable control in every degree of freedom, yet significant improvements are needed for effective, feasible operation with multi-purpose in-vitro studies. Future work will focus on shaft reinforcement, expansion of DOFs, TAVR and ablation testing, and voice control integration to further the purposes of this prototype towards safe, effective minimally invasive cardiac interventions.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bazán Palacios, Noé

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Bazán Palacios, Noé. (2025). Design And Guidance Testing Of A 3+Dof Robotic Adaptable Catheter System For Minimally Invasive Surgery. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/279193.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Bazán Palacios, Noé. Design And Guidance Testing Of A 3+Dof Robotic Adaptable Catheter System For Minimally Invasive Surgery. 2025. https://hdl.handle.net/11299/279193